Advanced Photonics Nexus, Volume. 3, Issue 5, 056011(2024)
Multimodal fiber antenna for proximity and stress sensing Article Video , On the Cover
Fig. 1. Application areas of multimodal fiber antenna sensor including environmental monitoring, biomedical applications, human–robot interactions, and cyber–physical systems. Figure created with permission from Ref. 17.
Fig. 2. (a) Thermal drawing of the multimodal fiber antenna sensor. (b) The preform fabrication steps. (c)-i. Cross-sectional image of the fiber sensor under an optical microscope (4× magnification,
Fig. 3. (a) Electromagnetic coupling scheme of multimodal fiber antenna sensor and TDR. (b) Principle of pressure sensing of fiber sensor by change in the capacitance due to change in the distance between metal wires. (c). Principle of proximity sensing of fiber sensor by change in the dielectric environment of the fiber.
Fig. 4. Electromagnetic field FEM simulation using COMSOL Multiphysics. (a)-i. Field surrounding the fiber sensor at fiber mode 0 (symmetric). (a)-ii. Field surrounding the fiber sensor at fiber mode 1 (antisymmetric). (b)-i. Field surrounding the fiber sensor at fiber mode 0 with the presence of a foreign object within the fiber’s diffraction limit. (b)-ii. Field surrounding the fiber sensor at fiber mode 1 with a foreign object within the fiber’s diffraction limit. The simulations are conducted at a frequency of 18 GHz, a characteristic median frequency for pulses generated by electronics operating in a frequency band of up to 35 GHz. The fiber device cladding has a filleted-corner square cross section with a side of
Fig. 5. TDR measurements of the multimodal fiber antenna under different configurations. (a) The sensitivity curve when the metal wires are placed horizontally (horizontal configuration). Inset, an example of a measurement with 100 gr. (b) The sensitivity curve when the metal wires are placed vertically (vertical configuration). Inset, an example of a measurement with 50 gr. (c) Sensitivity measurements in the vertical configuration, using light weights of 1, 2, and 5 gr. (d) Spatial resolution in the vertical configuration. (e) Distributed pressure measurement using 50 gr at 9.5, 17, 27.5, 37.5, and 47 cm in the vertical configuration. (f) Proximity measurement without the plastic pedestal used in the pressure measurements. The weights used in this case have a footprint diameter of 7 and 18 mm for the 2 and 50 gr weights, respectively. In addition, an index finger with a width of
Fig. 6. Signal analysis of fiber antenna evaluating dispersion and sensitivity. (a) The refractive indices of the fiber at antisymmetric and symmetric modes are simulated at the frequency range of 0.8 to 35 GHz by COMSOL Multiphysics simulations. 0.8 and 1 GHz results of mode refractive index have error bars indicating increasing sensitivity to the mesh fineness. (b) Signal-to-noise graphic of the fiber antenna with vertical wire configuration using 1 to 50 gr weights indicates an increase in noise relevant to an increase in signal. The power function fitting shows the sensitivity limit of the fiber antenna as 0.26 kPa.
|
Get Citation
Copy Citation Text
Merve Gokce, Eilam Smolinsky, Louis Alexandre van der Elst, Jillian Noblet, Creasy Clauser Huntsman, Alexander Gumennik, "Multimodal fiber antenna for proximity and stress sensing," Adv. Photon. Nexus 3, 056011 (2024)
Category: Research Articles
Received: Apr. 18, 2024
Accepted: Jul. 8, 2024
Published Online: Aug. 19, 2024
The Author Email: Alexander Gumennik (gumennik@iu.edu)