Acta Optica Sinica, Volume. 44, Issue 5, 0512002(2024)

Physicochemical Characteristics of Accumulated Dust on Mirror Surface and Its Influence on Fresnel High Magnification Focused Photovoltaic/Thermal System

Yahui Wang*, Rilige Su, Ning Zhao, Xiaoyan Zhao, and Yunfeng Qiu
Author Affiliations
  • College of Energy and Power Engineering, Inner Mongolia University of Technology, Huhhot010051, Inner Mongolia , China
  • show less
    Figures & Tables(13)
    Fresnel high magnification focused photovoltaic/thermal system
    Electrical power data and fitting curve of high magnification focused photovoltaic/thermal system
    Particles SEM images. (a) Calcite; (b) albite; (c) marble; (d) coal gangue; (e) carbon coke; (f) loess
    XRD diagrams of dust particles. (a) Calcite; (b) albite; (c) marble; (d) coal gangue; (e) carbon coke; (f) loess
    EDS spectra of dust particles and proportion of element type
    Electrical performance of Fresnel high magnification focused photovoltaic/thermal system after mirror deposition. (a) Calcite; (b) albite; (c) marble; (d) coal gangue; (e) carbon coke; (f) loess
    Average electrical efficiency curves of Fresnel high magnification focused photovoltaic/thermal system after mirror deposition of particles. (a) Calcite; (b) albite; (c) marble; (d) coal gangue; (e) carbon coke; (f) loess
    Thermal output performance of Fresnel high magnification focused photovoltaic/thermal system after mirror deposition. (a) Calcite; (b) albite; (c) marble; (d) coal gangue; (e) carbon coke; (f) loess
    Thermal output performance of Fresnel high magnification focused photovoltaic/thermal system after mirror deposition. (a) Calcite; (b) albite; (c) marble; (d) coal gangue; (e) carbon coke; (f) loess
    Analysis results of grey correlation degree of material composition
    Analysis results of grey correlation degree of element composition
    • Table 1. Physicochemical properties test equipment

      View table

      Table 1. Physicochemical properties test equipment

      EquipmentTypeParameterManufacturer
      EDSGENESISBe4-Es99EDAX Inc.
      SEMS3400NSE resolution:10 nm(3 kV)Hitachi limited
      XRDSmartLab-SERange of angular deviation is -0.01°-0.01°Rigaku corporation
    • Table 2. Measuring range and accuracy of data acquisition equipment

      View table

      Table 2. Measuring range and accuracy of data acquisition equipment

      InstrumentMeasuring rangeAccuracy
      Thermocouple /℃-20-100±0.4
      Platinum resistor /℃-20-100±0.1
      Turbine flowmeter /(m3/h)0.02-1.20<0.5%
      Anemograph /(m/s)0-600.1
      Solar irradiance meter /(W/m20-4000<5%
      Voltmeter /V0-2500.1
      Amperemeter /A0-300.1
    Tools

    Get Citation

    Copy Citation Text

    Yahui Wang, Rilige Su, Ning Zhao, Xiaoyan Zhao, Yunfeng Qiu. Physicochemical Characteristics of Accumulated Dust on Mirror Surface and Its Influence on Fresnel High Magnification Focused Photovoltaic/Thermal System[J]. Acta Optica Sinica, 2024, 44(5): 0512002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Nov. 16, 2023

    Accepted: Dec. 25, 2023

    Published Online: Mar. 15, 2024

    The Author Email: Wang Yahui (wang_yahui@imut.edu.cn)

    DOI:10.3788/AOS231799

    CSTR:32393.14.AOS231799

    Topics