Infrared and Laser Engineering, Volume. 51, Issue 10, 20210803(2022)

Optical coherence tomography technology for diagnosis of diseases in organs

Li Su1, Kaiwen Song2, Peitong Lv2, Haoran Wang2, Mingyang Sun2, Xiaotong Zhang2, and Tianyu Zhang2、*
Author Affiliations
  • 1Jilin Provincial Institute of Education, Changchun 130022, China
  • 2Key Laboratory of Geophysical Exploration Equipment, Ministry of Education, College of Instrumentation & Electrical Engineering, Jilin University, Changchun 130061, China
  • show less
    References(58)

    [1] Julian Armstrong, Matthew Leigh, Ian Walton, et al. In vivo size and shape measurement of the human upper airway using endoscopic longrange optical coherence tomography. Optics Express, 11, 1817-1826(2003).

    [2] Woo June Choi, Ruikang K Wang. In vivo imaging of functional microvasculature within tissue beds of oral and nasal cavities by swept-source optical coherence tomography with a forward/side-viewing probe. Biomed Opt Express, 5, 2620-2634(2014).

    [3] Kushal Wijesundara, Carlton Zdanski, Julia Kimbell, et al. Quantitative upper airway imaging with anatomic optical coherence tomography. Am J Respir Crit Care Med, 173, 226-233(2006).

    [4] Bahar Davoudi, Andras Lindenmaier, Beau A Standish, et al. Noninvasive in vivo structural and vascular imaging of human oral tissues with spectral domain optical coherence tomography. Biomed Opt Express, 3, 826-839(2012).

    [5] Adam M Zysk, Freddy T Nguyen, Amy L Oldenburg, et al. Optical coherence tomography: A review of clinical development from bench to bedside. Journal of Biomedical Optics, 12, 21-30(2007).

    [6] Robert A McLaughlin, Jonathan P Williamson, Martin J Phillips, et al. Applying anatomical optical coherence tomography to quantitative 3 D imaging of the lower airway. Opt Express, 16, 17521-17529(2008).

    [7] Yeh-Chan Ahn, Sung Won Kim, Sang Seok Hwang, et al. Optical imaging of subacute airway remodeling and adipose stem cell engraftment after airway injury. Biomed Opt Express, 5, 312-321(2013).

    [8] S Han, N H El-Abbadi, N Hanna, et al. Evaluation of tracheal imaging by optical coherence tomography. Respiration, 72, 537-541(2005).

    [9] Ridgway, M. J., Matthew Ridgway James, Ahuja Gurpreet, et al. Imaging of the pediatric airway using optical coherence tomography. Laryngoscope, 117, 2206-2212(2007).

    [10] J Jing, J Zhang, A C Loy, et al. High-speed upper-airway imaging using full-range optical coherence tomography. Journal of Biomedical Optics, 17, 110507(2012).

    [11] A D Lucey, A J C King, G A Tetlow, et al. Measurement, reconstruction, and flow-field computation of the human pharynx with application to sleep apnea. IEEE Trans Biomed Eng, 57, 2535-2548(2010).

    [12] B Ruofei, B Santosh, I Nicusor, et al. Airway compliance measured by anatomic optical coherence tomography. Biomed Opt Express, 8, 2195-2209(2017).

    [13] C J Joseph, Chou Lidek, Su Erica, et al. Anatomically correct visualization of the human upper airway using a high-speed long range optical coherence tomography system with an integrated positioning sensor. Sci Rep, 6, 39443(2016).

    [14] G K Sharma, G S Ahuja, M Wiedmann, et al. Long-range optical coherence tomography of the neonatal upper airway for early diagnosis of intubation-related subglottic injury. American Journal of Respiratory and Critical Care Medicine, 192, 1504-1513(2015).

    [15] Frances B Lazarow, Gurpreet S Ahuja, Loy Anthony Chin, et al. Intraoperative long range optical coherence tomography as a novel method of imaging the pediatric upper airway before and after adenotonsillectomy. Int J Pediatr Otorhinolaryngol, 79, 63-70(2015).

    [16] J H Walsh, M S Leigh, A Paduch, et al. Evaluation of pharyngeal shape and size using anatomical optical coherence tomography in individuals with and without obstructive sleep apnoea. J Sleep Res, 17, 230-238(2008).

    [17] Matthew S Leigh, Julian J Armstrong, Alexandre Paduch, et al. Anatomical optical coherence tomography for long-term, portable, quantitative endoscopy. IEEE Trans Biomed Eng, 55, 1438-1446(2008).

    [18] Kushal Wijesundara, Carlton Zdanski, Julia Kimbell, et al. Quantitative upper airway endoscopy with swept-source anatomical optical coherence tomography. Biomed Opt Express, 5, 788-799(2014).

    [19] Veronika Volgger, Giriraj K Sharma, Joseph C Jing, et al. Long-range Fourier domain optical coherence tomography of the pediatric subglottis. Int J Pediatr Otorhinolaryngol, 79, 119-126(2015).

    [20] Miranda Kirby, Keishi Ohtani, Taylor Nickens, et al. Reproducibility of optical coherence tomography airway imaging. Biomed Opt Express, 6, 4365-4377(2015).

    [21] D C Adams, L P Hariri, A J Miller, et al. Birefringence microscopy platform for assessing airway smooth muscle structure and function in vivo. Science Translational Medicine, 8, 359ra131(2016).

    [22] L Chou, A Batchinsky, S Belenkiy, et al. In vivo detection of inhalation injury in large airway using three-dimensional long-range swept-source optical coherence tomography. Journal of Biomedical Optics, 19, 036018(2014).

    [23] Li Qi, Shenghai Huang, Andrew E Heidari, et al. Automatic airway wall segmentation and thickness measurement for long-range optical coherence tomography images. Opt Express, 23, 33992-34006(2015).

    [24] Sang-Won Lee, Andrew E Heidary, David Yoon, et al. Quantification of airway thickness changes in smoke-inhalation injury using in-vivo 3-D endoscopic frequency-domain optical coherence tomography. Biomed Opt Express, 2, 243-254(2011).

    [25] [25] McNichols R J, Ashok Gowda, Brent A. Development of an endoscopic fluescence imageguided OCT probe f al cancer detection[C]Proceedings of SPIE The International Society f Optical Engineering, 2001, 6(4): 2330.

    [26] Suzanne C Whiteman, Ying Yang, van Pittius Daniel Gey, et al. Optical coherence tomography: real-time imaging of bronchial airways microstructure and detection of inflammatory/neoplastic morphologic changes. Clin Cancer Res, 12, 813-818(2006).

    [27] S D Murgu, H G Colt. Combined optical coherence tomography and endobronchial ultrasonography for laser-assisted treatment of postintubation laryngotracheal stenosis. Ann Otol Rhinol Laryngol, 122, 299-307(2013).

    [28] E Shostak, L P Hariri, G Z Cheng, et al. Needle-based optical coherence tomography to guide transbronchial lymph node biopsy. Journal of Bronchology & Interventional Pulmonology, 25, 189-197(2018).

    [29] L P Hariri, D C Adams, J C Wain, et al. Endobronchial optical coherence tomography for low-risk microscopic assessment and diagnosis of idiopathic pulmonary fibrosis in vivo. American Journal of Respiratory & Critical Care Medicine, 197, 949-952(2017).

    [30] Y Miao, J H Choi, L D Chou, et al. Automatic proximal airway volume segmentation using optical coherence tomography for assessment of inhalation injury. Journal of Trauma and Acute Care Surgery, 87, S132-S137(2019).

    [31] J H Choi, L D Chou, T R Roberts, et al. Point-of-care endoscopic optical coherence tomography detects changes in mucosal thickness in ARDS due to smoke inhalation and burns. Burns, 45, S89-S97(2019).

    [32] [32] Sheet D, Banerjee S, Phani S, et al. Transfer learning of tissue photon interaction in optical coherence tomography towardsin vivo histology of the al mucosa[C]2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014:13891392.

    [33] Heidari Ae, S P Sunny, B James, et al. Optical coherence tomography as an oral cancer screening adjunct in a low resource settings. IEEE Journal of Selected Topics in Quantum Electronics, 25, 7202008(2019).

    [34] A Sergeev, V Gelikonov, G Gelikonov, et al. In vivo endoscopic OCT imaging of precancer and cancer states of human mucos. Optics Express, 1, 432-440(1997).

    [35] Lee Cheng-Kuang, Chi Ting-Ta, Wu Chiung-Ting, et al. Diagnosis of oral precancer with optical coherence tompgraphy. Biomed Opt Express, 3, 1632-1646(2012).

    [36] [36] Nagarajan N, Vasantha J R, Raj J G, et al. A novel design of PCF f supercontinuum source to detect al cancer using OCT[C]2015 International Conference on Microwave Photonics (ICMAP), 2015.

    [37] Lee Amd, L Cahill, K Liu, et al. Wide-field in vivo oral OCT imaging. Biomed Opt Express, 6, 2664-2674(2015).

    [38] [38] Sinescu C, Duma V F, Canjau S, et al. Dentistry investigations of teeth dental prostheses using OCT[C]SPIE Photonics Europe, 2016.

    [39] P M Andrews, H W Wang, J Wierwille, et al. Optical coherence tomography of the living human kidney. Journal of Innovative Optical Health Sciences, 7, 1350064(2014).

    [40] [40] Li Qian, Onozato Maristela, rews Peter M, et al. Threedimensional highresolution optical coherence tomography (OCT) imaging of human kidney[C]International Conference of the IEEE Engineering in Medicine & Biology Society, 2009: 57415743.

    [41] Mara Buijs, Peter G K Wagstaff, Bruin Daniel M de, et al. An in-vivo prospective study of the diagnostic yield and accuracy of optical biopsy compared with conventional renal mass biopsy for the diagnosis of renal cell carcinoma: The interim analysis. Eur Urol Focus, 4, 978-985(2018).

    [42] [42] Chihhao Liu, Yong Du, Manmohan Singh, et al. Combined optical coherence tomography optical coherence elastography f glomerulonephritis classification[C]SPIE BiOS, 2016.

    [43] Zhenhe Ma, Ning Ding, Yao Yu, et al. Quantification of cerebral vascular perfusion density via optical coherence tomography based on locally adaptive regional growth. Appl Opt, 57, 10117-10124(2018).

    [44] S Glaßer, T Hoffmann, A Boese, et al. Virtual inflation of the cerebral artery wall for the integrated exploration of OCT and histology data. Computer Graphics Forum, 36, 57-68(2017).

    [45] V. Semyachkina-Glushkovskaya Oxana, V. Lychagov Vladislav, A. Bibikova Olga, et al. The assessment of pathological changes in cerebral blood flow in hypertensive rats with stress-induced intracranial hemorrhage using Doppler OCT: Particularities of arterial and venous alterations. Photonics and Lasers in Medicine, 2, 109-116(2013).

    [46] A D Aguirre, Y Chen, J G Fujimoto, et al. Depth-resolved imaging of functional activation in the rat cerebral cortex using optical coherence tomography. Optics Letters, 31, 3459-3461(2006).

    [47] W Chen, C Du, Y Pan. Cerebral capillary flow imaging by wavelength-division-multiplexing swept-source optical Doppler tomography. J Biophotonics, 11, 201800004(2018).

    [48] C Rodriguez, J I Szu, M M Eberle, et al. Decreased light attenuation in cerebral cortex during cerebral edema detected using optical coherence tomography. Neurophotonics, 1, 025004(2014).

    [49] S Askaruly, Y Ahn, H Kim, et al. Quantitative evaluation of skin surface roughness using optical coherence tomography in vivo. IEEE Journal of Selected Topics in Quantum Electronics, 25, 7202308(2019).

    [50] M Mogensen, L Thrane, T M Jørgensen, et al. OCT imaging of skin cancer and other dermatological diseases. Journal of Biophotonics, 2, 442-451(2010).

    [51] M Ziolkowska, C M Philipp, J Liebscher, et al. OCT of healthy skin, actinic skin and NMSC lesions. Medical Laser Application, 24, 256-264(2009).

    [52] J Holmes, S Schuh, F L Bowling, et al. Dynamic optical coherence tomography is a new technique for imaging skin around lower extremity wounds. The International Journal of Lower Extremity Wounds, 18, 65-74(2019).

    [53] F H Silver, R G Shah. Mechanical spectroscopy and imaging of skin components in vivo: Assignment of the observed moduli. Skin Res Technol, 25, 47-53(2019).

    [54] S M Jansen, B De, B H M I Van, et al. Optical techniques for perfusion monitoring of the gastric tube after esophagectomy: A review of technologies and thresholds. Diseases of the Esophagus Official Journal of the International Society for Diseases of the Esophagus, 31, 1-11(2018).

    [55] Q Ji, N Sudheendran, C H Liu, et al. Raman spectroscopy complements optical coherent tomography in tissue classification and cancer detection. Biological Trace Element Research, 12, 2078539(2015).

    [56] M. Jansen Sanne, Almasian Mitra, S. Wilk Leah, et al. Feasibility of optical coherence tomography (OCT) for intra-operative detection of blood flow during gastric tube reconstruction. Sensors (Basel), 18, 1331(2018).

    [57] X Yu, Y Luo, X Liu, et al. Towards high speed imaging of cellular structures in rat colon using micro-optical coherence tomography. IEEE Photonics Journal, 8, 3900308(2016).

    [58] Tsung-Han Tsai, Hsiang-Chieh Lee, Osman O Ahsen, et al. Ultrahigh speed endoscopic optical coherence tomography for gastroenterology. Biomed Opt Express, 5, 4387-4404(2014).

    CLP Journals

    [1] Yukang Shu, Chao Zhao, Xiaoyu Du, Xiang He, Hang Zhao, Xiaofeng Shi, Jun Ma. Depth extension technique of spectral domain optical coherence tomography[J]. Infrared and Laser Engineering, 2024, 53(4): 20230720

    Tools

    Get Citation

    Copy Citation Text

    Li Su, Kaiwen Song, Peitong Lv, Haoran Wang, Mingyang Sun, Xiaotong Zhang, Tianyu Zhang. Optical coherence tomography technology for diagnosis of diseases in organs[J]. Infrared and Laser Engineering, 2022, 51(10): 20210803

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical imaging

    Received: Dec. 20, 2021

    Accepted: --

    Published Online: Jan. 6, 2023

    The Author Email: Zhang Tianyu (zty@jlu.edu.cn)

    DOI:10.3788/IRLA20210803

    Topics