Photonics Research, Volume. 1, Issue 3, 124(2013)
Flood-illuminated adaptive optics ophthalmoscope with a single curved relay mirror
Fig. 1. Schematic of the single curved mirror AO ophthalmoscope. M1 is the curved mirror. L1 is an imaging lens. P is the focal point of the mirror. A polarization beam splitter (PBS) divides the light into two orthogonal polarization components, the S and P polarization components. The linearly polarized light whose direction is along the axis of the liquid crystal molecules will be used for correction and imaging. The light polarized orthogonally is received by the wavefront sensor for wavefront detection.
Fig. 2. There are two sets of conjugate planes. One set is formed by the illumination source, the retina, and the CCD imaging planes. The other set is constituted by the pupil of the eye, the LC-SLM, and the wavefront sensor planes. (a) Commonly used
Fig. 3. Calculated wavefront of (a) the sensor and (b) the corrector by ZEMAX. The difference of the RMS values between them is
Fig. 4. Schematic diagram of closed-loop optical configuration for measuring the response matrix. A point source is positioned at the imaging CCD and the light is propagated to the LC-SLM backward. The S polarization component is modulated and then it is turned into the P component by the half-wave plane (HWP). The P component can penetrate the PBS, and the unmodulated S component is abandoned. The quarter-wave plane (QWP) is carefully adjusted to make sure that the plane of polarization is rotated by 90° after the light traverses it twice. The P component becomes the S component on the way back and can be reflected to the wavefront sensor for measuring.
Fig. 5. Spot diagrams of the optical configuration on the imaging CCD plane, with (a) a spherical mirror, (b) a parabolic mirror, and (c) a hyperbolic mirror with conic constant
Fig. 6. Wavefront of (a) the model eye and (b) the subject. The numbers on the bar represent the peak-to-valley (PV) wavefront error in wavelength (
Fig. 7. Three images are of the same location in the retina, about 3.5° from the foveal center. (a) Retina before the AO compensation. (b) Photoreceptors after the AO compensation. (c) Blood vessels after the AO compensation (
Fig. 8. Power spectra of the images with and without AO compensation are shown in (a) and (b), respectively.
Fig. 9. Image registration of different fields. There is a 70 μm displacement on the retina between the two fields.
Get Citation
Copy Citation Text
Ruixue Liu, Yue Qi, Xianliang Zheng, Mingliang Xia, and Li Xuan, "Flood-illuminated adaptive optics ophthalmoscope with a single curved relay mirror," Photonics Res. 1, 124 (2013)
Category: Adaptive Optics
Received: Jul. 5, 2012
Accepted: Aug. 1, 2013
Published Online: Nov. 8, 2013
The Author Email: and Li Xuan (xuanli_lcao@163.com)