Acta Photonica Sinica, Volume. 51, Issue 12, 1211002(2022)

Underwater Modeling and Calibration Method of Binocular Stereo Vision Imaging System

Jianye LIU, Sufeng ZHUANG, Dawei TU*, Can ZHANG, and Pan JIN
Author Affiliations
  • School of Mechatronics Engineering and Automation,Shanghai University,Shanghai 200072,China
  • show less
    Figures & Tables(19)
    Underwater camera imaging light path
    Four-dimensional parametric expression of light
    Refraction imaging model of underwater camera
    Underwater binocular stereo vision model
    Schematic of multi-layer refraction light path
    Calibration results under different background light
    Simulation model
    X,Y,Z error distribution of three dimensional points
    Experimental environment
    Calibration scene in air
    Underwater calibration scene
    A set of images taken by underwater calibration
    Reprojection error of different test images
    Diagram of the 10 positions of the bat
    Schematic of experimental results
    • Table 1. Simulation calibration results

      View table
      View in Article

      Table 1. Simulation calibration results

      Truth valueInitial valueOptimization
      n0-0.161-0.006
      0-0.109-0.013
      10.9810.999
      d03038.12130.191
      Mean reprojection error05.8890.078
    • Table 2. Calibration paraments in camera air

      View table
      View in Article

      Table 2. Calibration paraments in camera air

      ParametersLeft cameraRight camera
      fxfy[1 453.090,1 453.096][1 450.469,1 450.299]
      cxcy[1 010.749,777.474][1 037.753,798.426]
      k1k2k3[0.014,0.006,-0.001][0.014,0.008,0.001]
      p1p2[-0.002,-0.020][-0.001,-0.024]
      Mean reprojection error0.0390.039
      Ra(-0.046,0.451,-0.017)
      Ta(-1147.532,5.206,257.982)
    • Table 3. Underwater calibration parameter

      View table
      View in Article

      Table 3. Underwater calibration parameter

      ParametersLeft cameraRight camera
      n[-0.0035,-0.0301,0.9995][0.0049,-0.0292,0.9996]
      d021.63617.505
      Rw(-0.045,0.442,-0.030)
      Tw(-1 148.776,12.644,252.121)
    • Table 4. Measurement results of bat under 10 postures

      View table
      View in Article

      Table 4. Measurement results of bat under 10 postures

      Posturesd1ErrorSDd2ErrorSDdisErrorSD
      149.76-0.40.8150.630.50.6499.161.41.2
      150.150.1150.970.8498.771.1
      151.241.1149.93-0.20498.931.2
      150.290.2150.150.1498.390.7
      150.680.6151.151.1499.511.8
      150.950.8150.620.5498.460.7
      150.730.6150.920.8499.271.6
      150.850.7150.720.6498.130.4
      150.920.8150.350.2498.731.0
      151.921.8149.27-0.9499.341.6
    Tools

    Get Citation

    Copy Citation Text

    Jianye LIU, Sufeng ZHUANG, Dawei TU, Can ZHANG, Pan JIN. Underwater Modeling and Calibration Method of Binocular Stereo Vision Imaging System[J]. Acta Photonica Sinica, 2022, 51(12): 1211002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 29, 2022

    Accepted: Jun. 17, 2022

    Published Online: Feb. 6, 2023

    The Author Email: Dawei TU (tdw@shu.edu.cn)

    DOI:10.3788/gzxb20225112.1211002

    Topics