Acta Optica Sinica, Volume. 28, Issue 5, 889(2008)

Linearity Measurement of Accurate Photodetector

Chen Feng*, Li Shuang, Wang Ji, and Zheng Xiaobing
Author Affiliations
  • [in Chinese]
  • show less
    References(14)

    [1] [1] E. F. Zalewski, J. Geist. Silicon photodiode spectral response self-calibration[J]. Appl. Opt., 1980, 19(8): 1214~1216

    [2] [2] N. P. Fox. Radiometry with cryogenic radiometers and semiconductor photodiodes[J]. Metrologia, 1996, 32(6): 535~543

    [3] [3] N. P. Fox, C. J. Chunnilall, M. G. White. Detector based transfer standards for improved accuracy in spectral irradiance and radiance measurements[J]. Metrologia, 1998, 35(4): 555~561

    [4] [4] L. Werner, J. Fischer, U. Johannsen U et al.. Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer[J]. Metrologia, 2000, 37(4): 279~284

    [5] [5] L. Werner, R. Friedrich, U. Johannsen et al.. Precise scale of spectral responsivity for InGaAs detectors based on a cryogenic radiometer and several laser sources[J]. Metrologia, 2000, 37(5): 523~526

    [6] [6] B. N. Taylor, C. E. Kuyatt. Guidelines for evaluating and expressing the uncertainty of NIST measurement results. http:∥physics.nist.gov/pubs/guidelines

    [8] [8] Toomas Kübarsepp, Atte Haapalinna, Petri Krh et al.. Nonlinearity measurements of silicon photodetectors[J]. Appl. Opt., 1998, 37(13): 2716~2722

    [9] [9] Atte Haapalinna, Toomas Kübarsepp, Petri Krh et al.. Measurement of the adsolute linearity of photodetectors with a diode laser[J]. Meas. Sci. Technol., 1999, 10(11): 1075~1078

    [13] [13] C. L. Sanders. A photocell linearity tester[J]. Appl. Opt., 1962, 1(3): 207~211

    [14] [14] W. Budde. Multidecade,linearity measurements on Si photodiodes[J]. Appl. Opt., 1979, 18(10): 1555~1558

    [16] [16] D. A. Swyt, J. G. LaRock. Inverse-fourth apparatus for photometric calibrations[J]. Rev. Sci. Instrum., 1978, 49(8): 1083~1089

    [17] [17] R. C. Hawes. Technique for measuring photometric accuracy[J]. Appl. Opt., 1971, 10(6): 1246~1253

    [18] [18] C. L. Sanders. Accurate measurements of and corrections for nonlinearities in radiometers[J]. J. Res. Natl. Bur. Stand., 1972, 76(4): 437~455

    [19] [19] H. E. Bennett. Accurate method for detecting photometric linearity[J]. Appl. Opt., 1966, 5(8): 1265~1270

    CLP Journals

    [1] Zhao Weiqiang, Liu Hui, Liu Jian. Study on Nonlinearity Coefficient Measurement for Optical Detector Using Infrared LED[J]. Acta Optica Sinica, 2015, 35(9): 912002

    [2] Gao Yesheng, Quan Zhike, Zheng Guangjin, Shi Xueshun. Standard Design and Uncertainty Evaluation of Optical Fiber Power with High Accuracy[J]. Chinese Journal of Lasers, 2009, 36(s2): 140

    [3] Yang Benyong, Zhang Liming, Chen Hongyao, Qiao Yanli. System Design of the Integrating Sphere Used for on-Board Calibration of Visible-SWIR Hyperspectral Remote Sensors[J]. Acta Optica Sinica, 2009, 29(12): 3545

    [4] Yan Zhaoai, Hu Xiong, Guo Shangyong, Cheng Yongqiang, Wu Xiaocheng. Sodium Atoms D2 Line Doppler-Free Saturation Fluorescence Spectra Measurements[J]. Acta Optica Sinica, 2010, 30(4): 1036

    [5] Hui Liu, Hongyao Chen, Xiaolong Si, Liming Zhang. Linear Calibration of Wide Dynamic Range Response of Silicon Detectors Based on Double LEDs Light Source Integrating Sphere[J]. Acta Optica Sinica, 2017, 37(9): 0904001

    Tools

    Get Citation

    Copy Citation Text

    Chen Feng, Li Shuang, Wang Ji, Zheng Xiaobing. Linearity Measurement of Accurate Photodetector[J]. Acta Optica Sinica, 2008, 28(5): 889

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Aug. 24, 2007

    Accepted: --

    Published Online: May. 20, 2008

    The Author Email: Feng Chen (fchen@aiofm.ac.cn)

    DOI:

    Topics