Chinese Journal of Lasers, Volume. 41, Issue 8, 804002(2014)

High-Resolution Full-Field Optical Coherence Tomography for Biological Tissue

Zhu Yue* and Gao Wanrong
Author Affiliations
  • [in Chinese]
  • show less
    References(26)

    [1] [1] Huang D, Swanson E A, Lin C P, et al.. Optical coherence tomography[J]. Science, 1991, 254(5035): 1178-1181.

    [2] [2] Bian Haiyi, Gao Wanrong, Zhang Xianling, et al.. Reconstruction method based on the detected matrix for spectral-domain optical coherence tomography[J]. Acta Optica Sinica, 2014, 34(2): 0211003.

    [3] [3] Yang Liu, Hong Wei, Wang Chuan, et al.. Flow velocity measurement based on speckle in optical coherence tomography[J]. Chinese J Lasers, 2012, 39(5): 0504002.

    [5] [5] Ding Zhihua, Zhao Chen, Bao Wen, et al.. Advances in doppler optical coherence tomography[J]. Laser & Optoelectronics Progress, 2013, 50(8): 080005.

    [6] [6] Zhang Wei, Lu Yiming, Wu Linhui, et al.. Hemoglobin diffuse optical tomography for breast tumor diagnosis: phantom experiment and in vivo evaluation[J]. Acta Optica Sinica, 2013, 33(6): 0617001.

    [7] [7] Li Jianghua, Huang Hai, Tang Zhilie, et al.. Measurement of enamel mineral density by optical coherence tomography[J]. Acta Optica Sinica, 2013, 33(8): 0817001.

    [8] [8] Beaurepaire E, Boccara A C, Lebec M, et al.. Full-field optical coherence microscopy[J]. Opt Lett, 1998, 23(4): 244-246.

    [9] [9] Dubois A, Vabre L, Boccara A C, et al.. High-resolution full-field optical coherence tomography with a Linnik microscope[J]. Appl Opt, 2002, 41(4): 805-812.

    [10] [10] Dubois A, Moneron G, Grieve K, et al.. Three-dimensional cellular-level imaging using full-field optical coherence tomography[J]. Physics in Medicine and Biology, 2004, 49(7): 1227-1234.

    [11] [11] Zheng J, Lu D, Chen T, et al.. Label-free subcellular 3D live imaging of preimplantation mouse embryos with full-field optical coherence tomography[J]. Journal of Biomedical Optics, 2012, 17(7): 0705031.

    [12] [12] Vabre L, Dubois A, Boccara A C. Thermal-light full-field optical coherence tomography[J]. Opt Lett, 2002, 27(7):530-532.

    [13] [13] Hariharan P, Roy M. White-light phase-stepping interferometry for surface profiling[J].Journal of Modern Optics, 1994, 41(11): 2197-2201.

    [14] [14] Latrive A, Boccara C. Flexible and rigid endoscopy for high-resolution in-depth imaging with Full-Field OCT[C]. Biomedical Optics, OSA, 2012: BTu4B.4.

    [15] [15] Lu S H, Wang C Y, Hsieh C Y, et al.. Full-field optical coherence tomography using nematic liquid-crystal phase shifter[J]. Appl Opt, 2012, 51(9): 1361-1366.

    [16] [16] Dubois A, Grieve K, Moneron G, et al.. Ultrahigh-resolution full-field optical coherence tomography[J]. Appl Opt, 2004, 43(14): 2874-2883.

    [17] [17] Watanabe Y, Hayasaka Y, Sato M, et al.. Full-field optical coherence tomography by achromatic phase shifting with a rotating polarizer[J]. Appl Opt, 2005, 44(8): 1387-1392.

    [18] [18] Moreau J, Loriette V, Boccara A C. Full-field birefringence imaging by thermal-light polarization-sensitive optical coherence tomography II. Instrument and results[J].Appl Opt, 2003, 42(19):3811-3818.

    [19] [19] Zhu Rihong, Chen Lei, Wang Qing, et al.. Phase-shift interferometry and its application[J]. Journal of Applied Optics, 2006, 27(2): 85-88.

    [20] [20] Yang Yaliang. Full Field Optical Coherence Tomography[D]. Hangzhou: Zhejiang University, 2008. 44-46.

    [21] [21] Goodman J W. Statistical Optics[M]. New York: Wiley-Interscience, 1985.

    [22] [22] Kino G S, Chim S S C. Mirau correlation microscope[J]. Appl Opt, 1990, 29(26): 3775-3783.

    [23] [23] Wang Rui. Optical Coherence Tomography and Its Application in Embryonic Develspment[D]. Beijing: Tsinghua University, 2006. 38-39.

    [24] [24] Yu Daoyin, Tan Hengying. Engineering Optics[M]. Beijing: China Machine Press, 1991. 347-348.

    [25] [25] Safrani A, Abdulhalim I. Ultrahigh-resolution full-field optical coherence tomography using spatial coherence gating and quasi-monochromatic illumination[J]. Opt Lett, 2012, 37(4): 458-460.

    [26] [26] Xiao Qing. Development of Ultrahigh-Resolution, Real-Time Optical Coherence Tomography System[D]. Wuhan: Huazhong University of Science and Technology, 2011. 30-31.

    CLP Journals

    [1] Xie Bingkai, Liu Shaojie, Wu Yongbo, Tang Zhilie. Dual Mode Imaging of All-Optical Non-Contact Photoacoustic Tomography and Optical Coherence Tomography[J]. Acta Optica Sinica, 2016, 36(1): 111001

    [2] Gao Qiang, Zhang Chunguang, Wang Hao, Huang Junfeng. Hyperspectral Imaging of Human Gastric Parietal Cells Based on Narrowband AOTF[J]. Laser & Optoelectronics Progress, 2015, 52(12): 122205

    [3] Jiang Huilü, Liao Na, Li Chaohong, Li Yiyu, Chen Hao, Huang Jinhai, Wang Qinmei. High-Speed Compact Adaptive Optics Scanning Laser Ophthalmoscope[J]. Acta Optica Sinica, 2015, 35(11): 1117002

    [4] Liao Jiuling, Gao Wanrong. A Method of Improving Signal-to-Noise Ratio in Spectrally Encoded Microscopy[J]. Acta Optica Sinica, 2015, 35(3): 317001

    [5] Li Lin, Tang Zhilie, Wu Yongbo. Scattering Photoacoustic Detection Technique and Its Imaging Method[J]. Acta Optica Sinica, 2016, 36(9): 911002

    [6] Zhu Yue, Gao Wanrong, Guo Yingcheng. A Method of Improving Imaging Quality of Full-Field Optical Coherence Tomography[J]. Acta Optica Sinica, 2015, 35(5): 517001

    [7] Zhai Chengcheng, Zhang Bin, Qi Sisheng, Guo Wei, Yang Zhiyong, Yang Anping, Zhang Mingjie, Yang Yan, Yu Yi, Wang Rongping, Tao Guangming, Tang Dingyuan, Barry Luther-Davies. Fabrication and Properties of Flexible Chalcognide Fiber Image Bundles[J]. Acta Optica Sinica, 2015, 35(8): 806005

    [8] Hu Huijie, Gong Yan, Wu Xiaodong. Simulation about Influence of Specular Scattering on Microscope Objective Stray Light Characteristics[J]. Laser & Optoelectronics Progress, 2015, 52(10): 101104

    [9] Chen Yingzhou, Ji Ying, Xie Ming, Xu Yuanyuan, Han Hao, Bu Min, Wang Yawei. Phase Microscopy Imaging Method Based on Common-Path without Micro-Objective[J]. Laser & Optoelectronics Progress, 2015, 52(12): 121702

    [10] Ma Zhao, Liu Ying, Lian Ge. Semi-Empirical Model for Biological Tissue Diffuse Reflectance Measurement with Small Aperture[J]. Chinese Journal of Lasers, 2015, 42(3): 304001

    [11] Hu Yujie, Jiang Zhuqing, Zhao Ye, Huang Haochong, Wang Zhe. Characteristics of Shift-Multiplexing Complex Spectral Domain Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2015, 52(6): 61701

    [12] Hu Zhixiong, Hao Bingtao, Liu Wenli, Hong Baoyu. Research on Point Spread Function Phantom Fabrication and Application for Evaluating Resolution Performance of OCT Systems[J]. Acta Optica Sinica, 2015, 35(4): 417001

    [13] Yang Fan, fanGao Wanrong, Zhu Yue. Hilbert Transform in Full-Field Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2016, 53(11): 111102

    [14] Wang Xuanze, Yang Liangen, Zhai Zhongsheng, Wu Wenjun, Xu Zhongbao. An Optimal Method of Calculating Phase Shift Interference Step Based on Inter-Pixel Algorithm[J]. Acta Optica Sinica, 2015, 35(11): 1112008

    Tools

    Get Citation

    Copy Citation Text

    Zhu Yue, Gao Wanrong. High-Resolution Full-Field Optical Coherence Tomography for Biological Tissue[J]. Chinese Journal of Lasers, 2014, 41(8): 804002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: biomedical photonics and laser medicine

    Received: Jan. 15, 2014

    Accepted: --

    Published Online: Jul. 15, 2014

    The Author Email: Yue Zhu (daoxiaomi1991@163.com)

    DOI:10.3788/cjl201441.0804002

    Topics