Acta Optica Sinica, Volume. 38, Issue 4, 0430003(2018)

Raman Characteristic Peak Intensity Correction of Potassium Sorbate Based on Sodium Nitrate Internal Standard

Xiaoqian Fang, Yongyu Li*, Yankun Peng, Yan Li, Fan Wang, and Wenxiu Wang
Author Affiliations
  • National Research and Development Center for Agro-Processing Equipment, College of Engineering, China Agricultural University, Beijing 100083, China
  • show less
    Figures & Tables(8)
    Raman spectra of sodium nitrate standard plasmid, potassium sorbate standard plasmid, and solution sample consisted of sodium nitrate with mass fraction of 0.1 and potassium sorbate with mass fraction of 0.1
    Raman spectra of solution sample consisted of sodium nitrate with mass fraction of 0.1 and potassium sorbate with mass fraction of 0.1
    Original Raman spectra of 49 solution samples and Raman spectra of sodium nitrate sample with mass fraction of 0.1
    Raman spectra of 49 solution samples after correction
    Prediction results of (a) calibration set and (b) validation set in potassium sorbate optimum prediction model
    Prediction result of optimum prediction model of potassium sorbate in 18 validated samples
    • Table 1. Characteristic peak intensity of potassium sorbate before and after correction under different conditions in the same sample

      View table

      Table 1. Characteristic peak intensity of potassium sorbate before and after correction under different conditions in the same sample

      Test height /mmRunning time /hCharacteristic peak intensity of sodium nitrate(1053 cm-1)Relative change ratioCharacteristic peak intensity (1164 cm-1)Characteristic peak intensity (1399 cm-1)Characteristic peak intensity (1655 cm-1)
      Before correctionAfter correctionBefore correctionAfter correctionBefore correctionAfter correction
      7.5017491.00212421241561156150715071
      7.5+2.0015831.10189520931381152545064976
      7.5+4.0011371.54143322031010155233145096
      7.5+4.025852.997742313515153717415200
      7.5+4.044044.335022172376162711705065
      RSD /%46.994.4948.252.2748.071.43
    • Table 2. Comparison of linear regression prediction models of potassium sorbate standard solution

      View table

      Table 2. Comparison of linear regression prediction models of potassium sorbate standard solution

      Data sourceRaman shift /cm-1Linear equationRc2RMSEc /10-3Rp2RMSEp /10-3RSD /%RPD
      Raw data1164y=15.9692+0.0498x0.559618.89140.438721.042038.971.31
      1399y=16.3954+0.0693x0.598118.04740.448120.878438.661.32
      1655y=17.3176+0.0197x0.516918.34570.419121.324939.491.30
      Corrected raw data1164y=-1.5791+0.0489x0.98603.35380.97494.84399.665.76
      1399y=-0.9005+0.0671x0.98853.03840.98653.76437.507.41
      1655y=-0.1835+0.0204x0.98443.54490.97844.35668.686.40
    Tools

    Get Citation

    Copy Citation Text

    Xiaoqian Fang, Yongyu Li, Yankun Peng, Yan Li, Fan Wang, Wenxiu Wang. Raman Characteristic Peak Intensity Correction of Potassium Sorbate Based on Sodium Nitrate Internal Standard[J]. Acta Optica Sinica, 2018, 38(4): 0430003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Oct. 30, 2017

    Accepted: --

    Published Online: Jul. 10, 2018

    The Author Email: Yongyu Li (yyli@cau.edu.cn)

    DOI:10.3788/AOS201838.0430003

    Topics