Optics and Precision Engineering, Volume. 32, Issue 5, 694(2024)

Integrated platform for micro-vibration simulation and active-passive vibration isolation

Chao QIN1,3, Honghai ZHOU1,2,3, Shuai HE1,3, Zhenbang XU1,3、*, and He ZHU1,2,3
Author Affiliations
  • 1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun30033, China
  • 2University of Chinese Academy of Sciences, Beijing100049, China
  • 3Key Laboratory of On-orbit Manufacturing and Integration for Space Optics System, Chinese Academy of Sciences, Changchun100, China
  • show less
    Figures & Tables(16)
    Schematic diagram of integrated experimental platform for micro-vibration simulation and active-passive vibration isolation
    Finite element model of experimental platform
    First sixth modals of integrated experimental platform
    Principle for air-floating passive vibration isolation
    Effect of passive vibration isolation in different directions
    Principle of active vibration isolation based on feedback
    Active damping control loop
    Electronic control system
    Effect of active vibration isolation in different directions
    Distribution of sensors in micro-vibration simulated measurement
    Time domain simulation results of single frequency harmonic
    Test results of single frequency harmonic simulation
    Test results of multifrequency harmonic simulation
    • Table 1. Modals of integrated experimental platform

      View table
      View in Article

      Table 1. Modals of integrated experimental platform

      模态阶数固有频率/Hz振 型
      一阶5.5沿Z平动
      二阶6.2XY向复合平动
      三阶6.2XY向复合平动
      四阶6.7X轴摆动
      五阶9.8Z轴转动
      六阶9.9Y轴摆动
    • Table 2. Test results of single frequency harmonic simulation

      View table
      View in Article

      Table 2. Test results of single frequency harmonic simulation

      频率/Hz项 目平动加速度幅值/mg转动加速度幅值/(mrad·s-2
      XYZXYZ
      50目标值0.70.70.7606060
      实测值0.7050.7020.70260.22158.06660.005
      误差/%0.710.290.290.373.220.01
    • Table 3. Test results of multifrequency harmonic simulation

      View table
      View in Article

      Table 3. Test results of multifrequency harmonic simulation

      频率/Hz项 目平动加速度幅值/mg转动加速度幅值/(mrad·s-2
      XYZXYZ
      20目标值0.70.70.7606060
      实测值0.7070.7090.70157.70957.55157.488
      误差(%)1.001.290.143.824.084.19
      50目标值0.70.70.7606060
      实测值0.7050.7030.70260.19958.65159.994
      误差(%)0.710.430.290.332.250.01
      100目标值0.70.70.7606060
      实测值0.7120.6910.70360.31156.45960.417
      误差(%)1.711.290.430.525.900.70
    Tools

    Get Citation

    Copy Citation Text

    Chao QIN, Honghai ZHOU, Shuai HE, Zhenbang XU, He ZHU. Integrated platform for micro-vibration simulation and active-passive vibration isolation[J]. Optics and Precision Engineering, 2024, 32(5): 694

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Aug. 9, 2023

    Accepted: --

    Published Online: Apr. 2, 2024

    The Author Email: Zhenbang XU (xuzhenbang@ciomp.ac.cn)

    DOI:10.37188/OPE.20243205.0694

    Topics