Laser Technology, Volume. 48, Issue 5, 671(2024)

Improved iterative smoothing for correcting baseline in atomic emission spectra fitting algorithm

ZHANG Wenli1, SHI Xiudong1、*, YE Fanxiu2, and CHEN Hao1
Author Affiliations
  • 1School of Mechanical Engineering, Jiangnan University, Wuxi 214000, China
  • 2Wuxi Jinyibo Instrument Technology Co. Ltd., Wuxi 214000, China
  • show less
    References(13)

    [5] [5] HU H, BAI J, XIA G, et al. Improved baseline correction method based on polynomial fitting for raman spectroscopy[J]. Photonic Sensors, 2018, 8(4): 332-340.

    [6] [6] FENG X, ZHU Z, SHEN M, et al. The method of baseline drift co-rrection of Raman spectrum based on polynomial fitting[J]. Computers & Applied Chemistry, 2009, 26(6): 759-762.

    [8] [8] LIU J, LIU S L, MEDHAT M E. Wavelet transform theory: The mathematical principles of wavelet transform in gamma spectroscopy[J]. Radiation Physics and Chemistry, 2023, 203: 110592.

    [9] [9] BERTINETTO C G, VUORINEN T. Automatic baseline recognition for the correction of large sets of spectra using continuous wavelet transform and iterative fitting[J]. Applied Spectroscopy, 2014, 68(2): 155-164.

    [10] [10] ZHANG F, TANG X, TONG A, et al. An automatic baseline co-rrection method based on the penalized least squares method[J]. Sensors, 2020, 20(7): 2015-2026.

    [11] [11] YANG G, DAI J, LIU X, et al. Multiple constrained reweighted penalized least squares for spectral baseline correction[J]. Applied Spectroscopy, 2020, 74(12): 1443-1451.

    [12] [12] SHUANG B S, ZI Q Y, JIA X Z, et al. An improved dual asymmetric penalized least squares baseline correction method for high-noise spectral data analysis[J]. Nuclear Science and Engineering, 2023, 197(4): 589-600.

    [14] [14] ZHANG Q, LI H, XIAO H, et al. An improved PD-AsLS method for baseline estimation in EDXRF analysis[J]. Analytical Methods, 2021, 13(17): 2037-2043.

    [15] [15] HE Sh X, ZHANG W, LIU L J, et al. Baseline correction for Raman spectra using an improved asymmetric least squares method[J]. Analytical Methods, 2014, 6(12): 4402-4407.

    [16] [16] SUN L, YU H. Automatic estimation of varying continuum background emission in laser-induced breakdown spectroscopy[J]. Spectrochimica Acta Part, 2009, B64(3): 278-287.

    [19] [19] EILERS P H C. Parametric time warping[J]. Analytical Chemistry, 2004, 76(2): 404-411.

    [20] [20] FRIEDRICHS M S. A model-free algorithm for the removal of baseline artifacts[J]. Journal of Biomolecular NMR, 1995, 5: 147-153.

    [21] [21] TAN B, HUANG M, ZHU Q, et al. Detection and correction of laser induced breakdown spectroscopy spectral background based on spline interpolation method[J]. Spectrochimica Acta Part, 2017, B138: 64-71.

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Wenli, SHI Xiudong, YE Fanxiu, CHEN Hao. Improved iterative smoothing for correcting baseline in atomic emission spectra fitting algorithm[J]. Laser Technology, 2024, 48(5): 671

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Sep. 22, 2023

    Accepted: Dec. 2, 2024

    Published Online: Dec. 2, 2024

    The Author Email: SHI Xiudong (shixd5718@163.com)

    DOI:10.7510/jgjs.issn.1001-3806.2024.05.009

    Topics