Chinese Journal of Lasers, Volume. 47, Issue 5, 0504001(2020)

Ring-Down Cavity Adjustment Method Based on Transmission Spot Shape Monitoring

Ying Xue1,2,3, Xinghu Du1,2,3, Xing He1,2、*, Shuai Wang1,2, Ping Yang1,2, and Bing Xu1,2、**
Author Affiliations
  • 1Key Laboratory of Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences,Chengdu, Sichuan 610209, China
  • 2Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, Sichuan 610209, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    References(13)

    [1] Herbelin J M. McKay J A, Kwok M A, et al. Sensitive measurement of photon lifetime and true reflectances in an optical cavity by a phase-shift method[J]. Applied Optics, 19, 144-147(1980).

    [3] Rempe G, Lalezari R, Thompson R J et al. Measurement of ultralow losses in an optical interferometer[J]. Optics Letters, 17, 363-365(1992).

    [4] Uehara N, Ueda A, Ueda K et al. Ultralow-loss mirror of the parts-in-10 6 level at 1064 nm[J]. Optics Letters, 20, 530-532(1995).

    [5] Anderson D Z, Frisch J C, Masser C S. Mirror reflectometer based on optical cavity decay time[J]. Applied Optics, 23, 1238-1245(1984).

    [7] Han Y L, Li B C, Cui H et al. -07-22(2015).

    [8] He X. Study on precise and accurate measurement technique of high reflectivity Chengdu: Institute of Optics and Electronics,[D]. Chinese Academy of Sciences, 74-91(2016).

    [9] O'Keefe A. Deacon D A G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J]. Review of Scientific Instruments, 59, 2544-2551(1988).

    [10] Wang J D, Yu J, Mo Z Q et al. Numerical methods of mode selection in continuous-wave cavity ring-down spectroscopy[J]. Acta Physica Sinica, 68, 244201(2019).

    [11] Huang H F, Lehmann K K. Noise in cavity ring-down spectroscopy caused by transverse mode coupling[J]. Optics Express, 15, 8745-8759(2007).

    [12] Cui H, Li B C, Xiao S L et al. Simultaneous measurement of S- and P-polarization reflectivity using optical feedback cavity ringdown technique[J]. Journal of University of Electronic Science and Technology of China, 47, 307-310(2018).

    [13] Dong H W, Guo R M, Cui W C et al. Study on cavity ring-down spectroscopy based on folded cavity[J]. Chinese Journal of Lasers, 47, 0311001(2020).

    Tools

    Get Citation

    Copy Citation Text

    Ying Xue, Xinghu Du, Xing He, Shuai Wang, Ping Yang, Bing Xu. Ring-Down Cavity Adjustment Method Based on Transmission Spot Shape Monitoring[J]. Chinese Journal of Lasers, 2020, 47(5): 0504001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Nov. 2, 2019

    Accepted: Dec. 19, 2019

    Published Online: May. 12, 2020

    The Author Email: He Xing (hexingjiayou@126.com), Xu Bing (bing_xu_ioe@163.com)

    DOI:10.3788/CJL202047.0504001

    Topics