High Power Laser and Particle Beams, Volume. 35, Issue 8, 086001(2023)

A simulation study of two-dimensional anti-scatter grid in container CT inspection system

Wei Zou1, Guoping Zhu1, Yunlong Ling1, Chunguang Zong1,2, Bicheng Liu1, Xi Yi1, Yiming Zhang1, Yanli Deng1, and Junli Li1,2、*
Author Affiliations
  • 1Nuctech Company Limited, Beijing 100084, China
  • 2Department of Engineering Physics, Tsinghua University, Beijing 100084, China
  • show less
    Figures & Tables(14)
    Container CT inspection system scheme
    Accelerator structure scheme
    Detector multi-column crystal layout
    Tungsten spacer scheme
    Geometric model of container CT inspection system
    Two-dimensional anti-scatter grid geometric model
    X-ray energy distribution
    CT test phantom geometric model
    Distribution of crystal energy deposition
    CWO crystal test phantom scan sinograms
    BGO crystal test phantom scan sinograms
    CWO crystal test phantom CT reconstruction image
    BGO crystal test phantom CT reconstruction image
    • Table 1. Scattered component energy deposition ratio result

      View table
      View in Article

      Table 1. Scattered component energy deposition ratio result

      componentenergy deposition ratio without 2D ASG/%energy deposition ratio with 2D ASG/%difference of with - without 2D ASG/%
      CWOBGOCWOBGOCWOBGO
      signal X-ray crystals52.95±0.0654.60±0.0453.72±0.0655.29±0.040.77±0.080.69±0.06
      scattered X-ray reflector3.28±0.011.68±0.013.23±0.011.66±0.01−0.05±0.01−0.02±0.01
      tungsten spacer15.29±0.0313.65±0.0213.19±0.0212.13±0.01−2.10±0.04−1.52±0.02
      cushion0.01±0.010.01±0.010.01±0.010.01±0.010.00±0.010.00±0.01
      other rows13.62±0.0216.41±0.0214.53±0.0217.21±0.020.91±0.030.80±0.03
      PCB board0.26±0.010.31±0.010.27±0.010.31±0.010.01±0.010.00±0.01
      base0.11±0.010.26±0.010.11±0.010.26±0.010.00±0.010.00±0.01
      appearance box 1.19±0.011.36±0.011.04±0.011.31±0.01−0.15±0.01−0.05±0.01
      others13.29±0.0211.72±0.0113.90±0.0211.82±0.010.61±0.03−0.10±0.01
    Tools

    Get Citation

    Copy Citation Text

    Wei Zou, Guoping Zhu, Yunlong Ling, Chunguang Zong, Bicheng Liu, Xi Yi, Yiming Zhang, Yanli Deng, Junli Li. A simulation study of two-dimensional anti-scatter grid in container CT inspection system[J]. High Power Laser and Particle Beams, 2023, 35(8): 086001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Nuclear Science and Engineering

    Received: Dec. 22, 2022

    Accepted: Mar. 28, 2023

    Published Online: Aug. 16, 2023

    The Author Email: Li Junli (lijunli@tsinghua.edu.cn)

    DOI:10.11884/HPLPB202335.220421

    Topics