Acta Optica Sinica, Volume. 33, Issue 8, 812004(2013)
Research on System Level Calibration Method of Multi-Band Filter Radiometer
[1] [1] H W Yoon, C E Gibson. Comparison of the absolute detector-based spectral radiance assignment with the current NIST-assigned spectral radiance of tungsten strip lamps[J]. Metrologia, 2000, 37(5): 429-432.
[5] [5] S W Brown, G P Eppeldauer, K R Lykke. Facility for spectral irradiance and radiance responsivity calibrations using uniform sources[J]. Appl Opt, 2006, 45(32): 8218-8237.
[6] [6] B C Johnson, S W Brown, G P Eppeldauer, et al.. System-level calibration of a transfer radiometer used to validate EOS radiance scales [J]. International J Remote Sensing, 2003, 24(2): 339-356.
[7] [7] J J Butler, R A Barnes. The use of transfer radiometers in validating the visible to shortwave infrared calibrations of radiance sources used by instruments in NASA′s earth observing system [J]. Metrologia, 2003, 40(1): S70-S77.
[8] [8] Zou Peng, Zheng Xiaobing, Wu Haoyu, et al.. Development of multi-band radiance standard transfer detector[J]. Acta Optica Sinica, 2011, 31(4): 0404002.
[9] [9] Li Zhaozhou. Studies of Highly Accurate Radiometric Calibration and Application Based on Radiance Standard Detector [D]. Hefei: Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, 2005.
[11] [11] Jin Weiqi, Hu Weijie. Radiometric Photometric Chromaticity and Its Measurement[M]. Beijing: Beijing Institute of Technology Press, 2006. 7-8.
[12] [12] Li Jianjun, Zheng Xiaobing, Lu Yunjun, et al.. Accurate calibration of the spectral responsivity of silicon trap detectors between 350 nm and 1064 nm [J]. Acta Physica Sinica, 2009, 58(9): 6273-6278.
[13] [13] Barry N Taylor, Chris E Kuyatt. Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results. NIST Technical Note 1297[M]. Darby: DIANE Publishing, 1994.
[14] [14] B N Holben, T F Eck, I Slutsker, et al.. AERONET—federated instrument network and data archive for aerosol characterization [J]. Remote Sensing of Environment, 1998, 66(1): 1-16.
[15] [15] Zhengqiang Li, Luc Blarel, Thierry Podrin, et al.. Transferring the calibration of direct solar irradiance to diffuse-sky radiance measurements for CIMEL sun-sky radiometers [J]. Appl Opt, 2008, 47(10): 1368-1377.
[16] [16] Nordine Souaidia, Christophe Pietras, Giulietta Fargion, et al.. Comparison of laser-based and conventional calibrations of sun photometers[C]. SPIE , 2003, 5155: 61-72.
Get Citation
Copy Citation Text
Zhang Yanna, Zheng Xiaobing, Li Jianjun, Zhang Wei. Research on System Level Calibration Method of Multi-Band Filter Radiometer[J]. Acta Optica Sinica, 2013, 33(8): 812004
Category: Instrumentation, Measurement and Metrology
Received: Mar. 13, 2013
Accepted: --
Published Online: Jul. 16, 2013
The Author Email: Zhang Yanna (zynbao@mail.ustc.edu.cn)