High Power Laser and Particle Beams, Volume. 35, Issue 11, 114002(2023)

Reconstruction algorithm for bunch longitudinal distribution of coherent transition radiation

Xiaoxiao Yuan1, Jia Li1, Wenbing Yan1, Zhaohui Ran1,2, Xin Yang1,2, Quantang Zhao1,2、*, Yang Zong1, Shuchun Cao1,2, and Zimin Zhang1,2
Author Affiliations
  • 1Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    References(24)

    [1] Zhang Lingyi, Zhuang Jiejia, Zhao Kui, . Fourth-generation light sources[J]. High Power Laser and Particle Beams, 13, 51-55(2001).

    [5] [5] BrownW J, ersonSG, BartyCP J, et al. Generation of high brightness Xrays with the PLEIADES Thomson Xray source[C]Proceedings of the 2003 Particle Accelerat Conference. 2003: 9597.

    [8] [8] Dowell D H, Bolton P R, Clendenin J E, et al. Slice emittance measurements at the SLAC Gun Test Facility[J]. Nuclear Instruments Methods in Physics Research Section A: Accelerats, Spectrometers, Detects Associated Equipment, 2003, 507(12): 327330.

    [9] Potylitsyn AP. Transition radiation and diffraction radiation. Similarities and differences[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 145, 169-179(1998).

    [11] [11] Paech A, Ackermann W, Weil T, et al. Numerical simulation of synchrotron radiation f bunch diagnostics[C]Proceedings of the 10th European Particle Accelerat Conference (EPAC 06). 2006: 10311033.

    [15] [15] Xiang Dao. Advanced beam measurements of emittance, bunch length, beam size f highbrightness electron beam[D]. Beijing: Tsinghua University, 2008

    [16] [16] Bian Yu. Subpicosecond electron bunch length measurements using coherent transition radiation at SXFEL[D]. Shanghai: University of Chinese Academy of Sciences (Shanghai Institute of Applied Physics Chinese Academy of Sciences), 2017

    [17] [17] Ran Zhaohui, Li Zhongping, Zhao Quantang, et al. Demonstration of high energy electron radiography with submicron spatial resolution[J]. Nuclear Instruments Methods in Physics Research Section A: Accelerats, Spectrometers, Detects Associated Equipment, 2021, 1015: 165769.

    [19] Ai Lei, Zhao Quantang, Zong Yang, . Study on electron bunch length measurement of Lanzhou high energy electron radiography experimental platform[J]. Atomic Energy Science and Technology, 56, 570-576(2022).

    [20] [20] Lai R, Sievers A J. On using the coherent far IR radiation produced by a gedparticle bunch to determine its shape: I analysis[J]. Nuclear Instruments Methods in Physics Research Section A: Accelerats, Spectrometers, Detects Associated Equipment, 1997, 397(23): 221231.

    [21] [21] FrhlichL. Bunch length measurements using a MartinPuplett interferometer at the VUVFEL[D]. Hamburg Department of Physics of the University, 2005.

    [22] [22] Pelliccia D, Sen T. A twostep method f retrieving the longitudinal profile of an electron bunch from its coherent radiation[J]. Nuclear Instruments Methods in Physics Research Section A: Accelerats, Spectrometers, Detects Associated Equipment, 2014, 764: 206214.

    [24] Zhao Quantang, Zhang Zimin, Cao Shuchun, . Status and progress of high energy electron radiography[J]. Atomic Energy Science and Technology, 53, 1651-1655(2019).

    Tools

    Get Citation

    Copy Citation Text

    Xiaoxiao Yuan, Jia Li, Wenbing Yan, Zhaohui Ran, Xin Yang, Quantang Zhao, Yang Zong, Shuchun Cao, Zimin Zhang. Reconstruction algorithm for bunch longitudinal distribution of coherent transition radiation[J]. High Power Laser and Particle Beams, 2023, 35(11): 114002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Aug. 11, 2023

    Accepted: Oct. 23, 2023

    Published Online: Dec. 26, 2023

    The Author Email: Zhao Quantang (zhaoquantang@impcas.ac.cn)

    DOI:10.11884/HPLPB202335.230263

    Topics