Laser & Optoelectronics Progress, Volume. 60, Issue 15, 1522003(2023)

Combined Sunlight and Occupancy Dynamic Lighting System Design in Offices

Xinjing Qin, Zhisheng Wang*, Manqun Zhang, Yue Feng, and Songhai Xu
Author Affiliations
  • Research Institute of Photonics, Dalian Polytechnic University, Dalian 116034, Liaoning, China
  • show less
    Figures & Tables(12)
    DIAlux simulation diagram of office
    Light distribution curve of lamps. (a) Polar coordinate light distribution curve; (b) rectangular coordinate light distribution curve
    Distribution map of control system in office
    Schematic diagram of lighting overlay
    Distribution of test points and lamps
    Luminance distribution map of office during daytime
    Luminance distribution map of office at night
    • Table 1. Office area attributes

      View table

      Table 1. Office area attributes

      ParameterDescriptionValue
      Length5.0 m
      Office spaceWidth8.0 m
      Height3.4 m
      WindowHeight1.8 m
      Width1.5 m
      LampInstallation height3.1 m
      θ3600 lm
      P32.5 W
      Tc5000 K
      Number6
      DeskLength2.0 m
      Width1.6 m
      Height1.0 m
    • Table 2. Sunlight illuminance distribution of each test point

      View table

      Table 2. Sunlight illuminance distribution of each test point

      Time

      Date

      12:00-13:00

      2022-07-08

      Test point

      Value /lx

      Test point

      Value /lx

      F1F2F3
      939685581
      F4F5F6
      829673572
    • Table 3. Luminance components of lamps at test points F1 and F3 during daytime

      View table

      Table 3. Luminance components of lamps at test points F1 and F3 during daytime

      Lamp testQ1Q2Q3Q4Q5Q6
      F1709513442504460440
      F2237479253211259216
      F3127191432126146197
      F4415381363642438364
      F5191227195217468235
      F6119138177120184425
    • Table 4. Luminance distribution of test points at night

      View table

      Table 4. Luminance distribution of test points at night

      Time

      Date

      20:00-21:00

      2022-07-08

      Test pointF1F2F3
      Value /lx518571538
      Test pointF4F5F6
      Value /lx516561534
    • Table 5. Luminance distribution of lamps at each test point at night

      View table

      Table 5. Luminance distribution of lamps at each test point at night

      Lamp testQ 1Q2Q3Q4Q5Q6
      F12758618212517
      F29027183271728
      F31884280152723
      F42126152798518
      F53117279327586
      F61528231888285
      Total450512446453517457
    Tools

    Get Citation

    Copy Citation Text

    Xinjing Qin, Zhisheng Wang, Manqun Zhang, Yue Feng, Songhai Xu. Combined Sunlight and Occupancy Dynamic Lighting System Design in Offices[J]. Laser & Optoelectronics Progress, 2023, 60(15): 1522003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Jul. 25, 2022

    Accepted: Aug. 15, 2022

    Published Online: Aug. 11, 2023

    The Author Email: Zhisheng Wang (wangzs@dlpu.edu.cn)

    DOI:10.3788/LOP222162

    Topics