Acta Optica Sinica, Volume. 43, Issue 23, 2317001(2023)

Concentration Quantification Method Based on Single-Wavelength Excitation via Grüneisen-Relaxation Nonlinear Photoacoustic Effect

Xiatian Wang1,2, Lü Shengmiao2, Zhihua Xie2, Jingqin Chen2, Xiaojing Gong2、**, and Liquan Dong1,3、*
Author Affiliations
  • 1Beijing Key Laboratory for Precision Optoelectronic Measurement Instrument and Technology, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
  • 2Research Center for Biomedical Optics and Molecular Imaging, Shenzhen Key Laboratory for Molecular Imaging, Guangdong Provincial Key Laboratory of Biomedical Optical Imaging Technology, CAS Key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, Guangdong , China
  • 3Yangtze Delta Region Academy of Beijing Institute of Technology (Jiaxing), Jiaxing 314019, Zhejiang , China
  • show less
    Figures & Tables(9)
    Error of concentration quantification results. (a) Triangle of error coefficients for linear and nonlinear methods; (b) concentration quantification error of two methods
    Schematic of experiment system
    Scatter diagrams of mass concentration-amplitude of red dye. (a) Linear signals; (b) nonlinear signals
    Experimental results of red dye. (a) Results of concentration quantification; (b) relative error (absolute value)
    Scatter diagrams of mass concentration-signal amplitude of Rhodamine 6G. (a) Linear signal; (b) nonlinear signal
    Experimental results of Rhodamine 6G. (a) Results of concentration quantification; (b) relative error (absolute value)
    • Table 1. Simulation results of concentration quantification

      View table

      Table 1. Simulation results of concentration quantification

      RSB

      cm /

      (mg·mL-1

      cLm /

      (mg·mL-1

      cNm /

      (mg·mL-1

      1.001.002.001.41
      2.002.003.002.24
      3.003.004.003.16
      4.004.005.004.12
      5.005.006.005.10
    • Table 2. Signal amplitudes of red dye solution and blue dye solution

      View table

      Table 2. Signal amplitudes of red dye solution and blue dye solution

      SampleConcentration /(mg·mL-1Normalized amplitude of signalRSB_red
      LinearNonlinear
      Red dye20.200.021.11
      40.420.202.33
      60.640.423.56
      80.830.694.61
      101.001.005.56
      Blue dye60.180.04
    • Table 3. Signal amplitudes of Rhodamine 6G solution and hemoglobin solution

      View table

      Table 3. Signal amplitudes of Rhodamine 6G solution and hemoglobin solution

      SampleConcentration /(mg·mL-1Normalized amplitude of signalRSB_Rho6G
      LinearNonlinear
      Rhodamine 6G10.150.021.00
      20.230.131.53
      40.480.353.20
      60.760.625.07
      81.001.006.67
      Hemoglobin1500.150.02
    Tools

    Get Citation

    Copy Citation Text

    Xiatian Wang, Lü Shengmiao, Zhihua Xie, Jingqin Chen, Xiaojing Gong, Liquan Dong. Concentration Quantification Method Based on Single-Wavelength Excitation via Grüneisen-Relaxation Nonlinear Photoacoustic Effect[J]. Acta Optica Sinica, 2023, 43(23): 2317001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Medical optics and biotechnology

    Received: Jul. 27, 2023

    Accepted: Aug. 30, 2023

    Published Online: Dec. 12, 2023

    The Author Email: Gong Xiaojing (xj.gong@siat.ac.cn), Dong Liquan (kylind@bit.edu.cn)

    DOI:10.3788/AOS231317

    Topics