Acta Optica Sinica, Volume. 44, Issue 4, 0411001(2024)

Calibration Method of Camera Response Function Based on Multi-Exposure Image Sequence

Liuzheng Gao1,2, Banglei Guan1、*, Ang Su1、**, Zhang Li1, and Qifeng Yu1
Author Affiliations
  • 1College of Aerospace Science and Engineering, National University of Defense Technology, Changsha 410072, Hunan , China
  • 2Jiuquan Satellite Launch Center, Jiuquan 735000, Gansu , China
  • show less
    Figures & Tables(10)
    Public data set of Office
    CRF calibration results for Office data set. (a) Traditional calibration method; (b) improved calibration method
    Window data set taken with Daheng industrial camera
    CRF calibration results for Window data set. (a) Traditional calibration method; (b) improved calibration method
    Relative quantum absorptivity versus wavelength for three color channels of Sony IMX265 color CMOS
    CRF calibrated at highest order of 5
    • Table 1. Partial calibration data sets resulting from three data selection methods

      View table

      Table 1. Partial calibration data sets resulting from three data selection methods

      RegularGrossbergRandom
      123456123456123456
      3691194248136117219
      3187189258332102217
      2889185217117183178
      2277177217217385136228
      2279181217116961158
      27101201217017254146
      25891892310920966167
      39125216331392322989186
    • Table 2. Selected data sets for improved calibration method

      View table

      Table 2. Selected data sets for improved calibration method

      Adjacent exposure level
      1-22-33-44-55-6
      5310133776497101147145226
      21642769669996143139229
      429343926710211015797173
      55107388485128146191137224
      5110310617892133679984160
      469637784276181225123201
      20534810092136548596172
      226563118169212629354107
    • Table 3. Exposure ratio between images of different exposure levels for Office data set

      View table

      Table 3. Exposure ratio between images of different exposure levels for Office data set

      MethodChannelExposure ratio
      1/22/33/44/55/6

      Traditonal

      method

      B-channel0.31940.35680.63740.66840.5174
      G-channel0.26520.35760.61150.61300.4455
      R-channel0.16880.30660.56180.55490.4098

      Improved

      method

      B-channel0.49530.53440.68040.68400.5119
      G-channel0.47340.49330.64880.65530.5319
      R-channel0.44550.47410.62470.63860.4931
    • Table 4. Exposure ratio between images of different exposure levels for Window data set

      View table

      Table 4. Exposure ratio between images of different exposure levels for Window data set

      MethodChannelExposure ratio
      1/22/33/44/55/6

      Traditonal

      method

      B-channel0.60130.54200.53600.52600.5417
      G-channel0.48180.46700.48980.49230.4930
      R-channel0.53390.49520.51870.50660.5054

      Improved

      method

      B-channel0.55100.53290.54700.54290.5327
      G-channel0.51760.49960.51170.50210.4889
      R-channel0.52180.51000.51810.51060.5104
    Tools

    Get Citation

    Copy Citation Text

    Liuzheng Gao, Banglei Guan, Ang Su, Zhang Li, Qifeng Yu. Calibration Method of Camera Response Function Based on Multi-Exposure Image Sequence[J]. Acta Optica Sinica, 2024, 44(4): 0411001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Oct. 23, 2023

    Accepted: Dec. 11, 2023

    Published Online: Feb. 23, 2024

    The Author Email: Guan Banglei (banglei.guan@hotmail.com), Su Ang (suang2008@126.com)

    DOI:10.3788/AOS231687

    Topics