Chinese Journal of Lasers, Volume. 36, Issue 10, 2493(2009)
Swept-Source Optical Coherence Tomography for Endoscopic Imaging with Wavelength-Encoding Probe
[1] [1] G. J. Tearney,M. E. Brezinski,B. E. Bouma et al.. In vivo endoscopic optical biopsy with optical coherence tomography[J]. Science,1997,276:2037-2039
[2] [2] J. G. Fujimoto,C. Pitris,S. A. Boppart et al.. Optical coherence tomography:an emerging technology for biomedical imaging and optical biopsy[J]. Neoplasia,2000,2(1):9-25
[3] [3] Y. S. Sabharwal,A. R. Rouse,L. Donaldson et al.. Slit-scanning confocal microendoscope for high-resolution in vivo imaging[J]. Appl. Opt.,1999,38:7133-7144
[4] [4] T. Matsunaga,Y. Kawakami,K. Namba et al.. Intraductal biopsy for diagnosis and treatment of intraductal lesions of the breast[J]. Cancer,2004,101:2164-2169
[5] [5] G. J. Tearney,M. Shishkov,B. E. Bouma. Spectrally encoded miniature endoscopy[J]. Opt. Lett.,2002,27:412-414
[6] [6] D. Yelin,S. H. Yun,B. E. Bouma et al.. Three-dimensional imaging using spectral encoding heterodyne interferometry[J]. Opt. Lett.,2005,30:1794-1796
[7] [7] J. T. Motz,D. Yelin,B. J. Vakoc et al.. Spectral- and frequency-encoded fluorescence imaging[J]. Opt. Lett.,2005,30:2760-2762
[8] [8] Dvir Yelin,W. Matthew White,Jason. T. Motz et al.. Three-dimensional miniature endoscopy[J]. Nature,2006,443:765-765
[9] [9] Dvir Yelin,W. Matthew White,Jason. T. Motz et al.. Spectral-domain spectrally-encoded endoscopy[J]. Opt. Express,2007,15:2432-2444
[10] [10] L. Froehly,S. N. Martin,T. Lasser et al.. Multiplexed 3D imaging using wavelength encoded spectral interferometry:a proof of principle[J]. Opt. Commun.,2003,222:127-136
[11] [11] L. Froehly,A. Bachmann,T. Lasserb et al.. Wavelength multiplexed spectral interferometry for endoscopic topographic imaging[C]. SPIE,2005,5864:586406
[12] [12] M. A. Choma,M. V. Sarunic,C. Yang et al.. Sensitivity advantage of swept source and Fourier domain optical coherence tomography[J]. Opt. Express,2003,11:2183-2189
[13] [13] R. Leitgeb,C. K. Hitzenberger,A. F. Fercher. Performance of Fourier domain vs. time domain optical coherence tomography[J]. Opt. Express,2003,11:889-894
Get Citation
Copy Citation Text
Wang Ling, Ding Zhihua, Wu Tong, Yang Yong. Swept-Source Optical Coherence Tomography for Endoscopic Imaging with Wavelength-Encoding Probe[J]. Chinese Journal of Lasers, 2009, 36(10): 2493
Category:
Received: Oct. 25, 2008
Accepted: --
Published Online: Oct. 23, 2009
The Author Email: Ling Wang (oxsp_0@163.com)