Journal of Quantum Optics, Volume. 25, Issue 2, 228(2019)

A Locking Cavity Method Based on Tilt locking Technology

HAO Dong-dong*, ZHAI Ze-hui, JIA Xin, LIU Zhi-qiang, and GUO Juan
Author Affiliations
  • [in Chinese]
  • show less
    References(21)

    [2] [2] Bondu F,Fritschel P,Mann C N,et al.Ultrahigh-spectral-purity Laser for the VIRGO Experiment[J].Opt Lett,1996,21(8):582-584.DOI:http:∥dx.doi.org/101364/OL.21000582.

    [3] [3] Grop S,Bourgeois P Y,Bazin N,et al.ELISA:A Cryocooled 10 GHz Oscillator with 10-15 Frequency Stability[J].Review of Scientific Instruments,2010,81(2):480-495.DOI: http:∥dx.doi.org/101063/13290631.

    [4] [4] Schneider K,Schiller S,Mlynek J,et al.11-W Single-frequency 532 nm Radiation by Second-harmonic Generation of a Miniature Nd:YAG Ring Laser[J].Opt Lett,1996,21(24):1999-2001.DOI:https:∥doi.org/101364/OL.21001999.

    [5] [5] Kaneda Y,Yarborough J M,Merzlyak Y.CW,Single-frequency 229 nm Laser Source for Cd-cooling by Harmonic Conversion[C].Spie Lase.International Society for Optics and Photonics,2015.DOI:http:∥dx.doi.org/101117/122076213.

    [6] [6] Young B C,Cruz F C,Itano W M,et al.Visible Lasers with Subhertz Linewidths[J].Phys Rev Lett,1999,82(82):3799-3802.DOI:http:∥dx.doi.org/101103/PhysRevLett.823799.

    [7] [7] Dinesan H,Fasci E,D’Addio A,et al.Characterization of the Frequency Stability of an Optical Frequency Standard at 139 μm Based Upon Noise-immune Cavity-enhanced Optical Heterodyne Molecular Spectroscopy[J].Opt Express,2015,23(2):1757-1766.DOI: http:∥dx.doi.org/101364/OE.23001757.

    [8] [8] Saulson P R.Fundamentals of Interferometric Gravitational Wave Detectors[M].WORLD SCIENTIFIC,1994.DOI:http:∥dx.doi.org/101142/2410.

    [9] [9] Li Y,Zhang X,Li Y.Progress of the Optical Techniques for Laser Interferometer Gravitational Wave Detector[J].Scientia Sinica,2017,47.DOI: http:∥dx.doi.org/101360/SSPMA2016-00297.

    [10] [10] Galzerano G,Marano M,Taccheo S,et al.21-microm Lasers Frequency Stabilized Against CO2 Lines:Comparison Between Fringe-side and Frequency-modulation Locking Methods[J].Opt Lett,2003,28(4):248-250.DOI:https:∥doi.org/101364/OL.28000248.

    [11] [11] Bateman J E,Murray R L D,Himsworth M,et al.Hnsch-Couillaud Locking of Mach-Zehnder Interferometer for Carrier Removal from a Phase-modulated Optical Spectrum[J].J Opt Soc Am B,2010,27(8):1530-1533.DOI:https:∥doi.org/101364/JOSAB.27001530.

    [12] [12] Vainio,Bernard J E,et al.Cavity-enhanced Optical Frequency Doubler based on Transmission-mode Hnsch-Couillaud Locking[J].Applied Physics B,2011,104(4):897-908.DOI:http:∥dx.doi.org/101007/s00340-011-4437-z.

    [13] [13] White A D.Frequency Stabilization of Gas Lasers[J].IEEE J Quantum Electron,1965,1(8):349-357.DOI:http:∥dx.doi.org/101109/JQE.19651072246.

    [14] [14] Wieman C E,Gilbert S L.Laser-frequency Stabilization using Mode Interference from a Reflecting Reference Interferometer[J].Opt Lett,1982,7(10):480-482.DOI:http:∥dx.doi.org/101364/OL.7000480.

    [15] [15] Zullo R,Giorgini A,Avino S,et al.Laser-frequency Locking to a Whispering-gallery-mode Cavity by Spatial Interference of Scattered Light[J].Opt Lett,2016,41(3):650-652.DOI:http:∥dx.doi.org/101364/OL.41000650.

    [16] [16] Black E D.An Introduction to Pound-Drever-Hall Laser Frequency Stabilization[J].American Journal of Physics,2001,69(1):79-87.DOI: http:∥dx.doi.org/101119/11286663.

    [20] [20] Su J,Jiao M,Xing J,et al.Design of Pound-Drever-Hall laser frequency stabilization system without phase shifter[C] International Symposium on Precision Engineering Measurement & Instrumentation.International Society for Optics and Photonics,2015.DOI:http:∥dx.doi.org/101117/122087005.

    [21] [21] Shaddock D A,Gray M B,McClelland D E.Frequency Locking a Laser to an Optical Cavity by Use of Spatial Mode Interference[J].Opt Lett,1999,24(21):1499-1501.DOI:http:∥dx.doi.org/101364/OL.24001499.

    [22] [22] You Y,Chiche R,Yan L X,et al.High Finesse Pulsed Optical Cavity Locking by Tilt-locking Technique[J].Rev Sci Instrum,2014,85(3):033102-033102-4.DOI:http:∥dx.doi.org/101063/14867247.

    [23] [23] Siegman A E.Mill Valley,Calif,Laser[M].University Science books,1986.DOI:103390/ijms11062546.

    [24] [24] Feng S,Winful HG.Physical Origin of the Gouy Phase Shift[J].Opt Lett,2001,26(8):485-487.DOI:http:∥dx.doi.org/101364/OL.26000485.

    [25] [25] Bancelin Stéphane,Van d K J N,Quigley A S,et al.Gouy Phase Shift Measurement using Interferometric Second-harmonic Generation[J].Optics Letters,2018,43(9):1958-1961.DOI: http:∥dx.doi.org/101364/OL.43001958.

    Tools

    Get Citation

    Copy Citation Text

    HAO Dong-dong, ZHAI Ze-hui, JIA Xin, LIU Zhi-qiang, GUO Juan. A Locking Cavity Method Based on Tilt locking Technology[J]. Journal of Quantum Optics, 2019, 25(2): 228

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 4, 2018

    Accepted: --

    Published Online: Mar. 9, 2020

    The Author Email: HAO Dong-dong (hdongdong7@163.com)

    DOI:10.3788/jqo20192502.0902

    Topics