Infrared and Laser Engineering, Volume. 51, Issue 7, 20220395(2022)

Research on real-time absolute radiometric calibration technology of infrared cameras

Yuan Lv1, Mingyu Cong1, Yini Zhao2, Kaiqing Niu2, and Ziwei Lu2
Author Affiliations
  • 1School of Astronautics, Harbin Institute of Technology, Harbin 150001, China
  • 2China Academy of Space Technology, Beijing 100094, China
  • show less
    Figures & Tables(15)
    Flow chart of infrared calibration
    Flow chart of site calibration scheme
    Absolute radiometric calibration coefficient
    On orbit cross calibration flow chart of infrared channel remote sensor
    TERRA-MODIS and spectral response of the infrared camera
    AQUA-MODIS and spectral response of the infrared camera
    MSG-SEVIRI and spectral response of the infrared camera
    Radiance contrast between TERRA-MODIS and the infrared camera
    Radiance contrast between AQUA-MODIS and the infrared camera
    Radiance contrast between SEVIRI and the infrared camera
    Comparison of cross calibration and site calibration results
    • Table 1. Error table of each link of site calibration

      View table
      View in Article

      Table 1. Error table of each link of site calibration

      Error sourceCalibration errorMeasurement errorAlgorithm errorErrorSensitivity coefficientError contribution
      Moisture content20%20%0.05%1.0%
      Surface radiance0.1%0.5%0.1%%0.52%1.0%0.52%
      Solar zenith angle1.0%1.0%0.1%0.1%
      Intrinsic model precision2.0%2.0%1.0%2.0%
      Water meter emissivity 0.1%0.1%%1.0%0.1%
      Land surface emissivity0.1%0.5%0.5%0.71%1.0%0.71%
      Satellite count value0.1%0.1%0.14%1.0%0.14%
      Least square method0.5%0.5%1.0%0.50%
      Total error2.46%
    • Table 2. Matching coefficients between thermal infrared channel of the infrared camera and MODIS and SEVIRI spectra

      View table
      View in Article

      Table 2. Matching coefficients between thermal infrared channel of the infrared camera and MODIS and SEVIRI spectra

      Infrared camera and sensor a0a1a2a3a4Relative error
      TERRA-modis0.2865(ch28) 0.0645 (ch29) 0.5952 (ch30) 0.3076 0.2146%
      AQUA-modis0.2705(ch28) 0.0865 (ch29) 0.5960 (ch30) 0.2970 0.2336
      SEVIRI0.0417(ch7.3) 0.1965 (ch8.7) 0.4962 (ch9.7) 0.2485 (ch10.8) 0.1097 0.3407%
    • Table 3. MSG2/SEVIRI calibration accuracy and matching coefficient

      View table
      View in Article

      Table 3. MSG2/SEVIRI calibration accuracy and matching coefficient

      NumberChannel nameCalibration accuracy/KMatching factor(a
      1ch7.30.40.2901
      2ch8.70.50.4593
      3ch9.70.60.1969
      4ch10.80.80.1219
    • Table 4. Error table of each link of cross calibration

      View table
      View in Article

      Table 4. Error table of each link of cross calibration

      Error sourceErrorSensitivity coefficientError contribution
      Data matching5.00%0.20%1.00%
      Spectral Matching0.50%1.00%0.50%
      Filter1.00%0.10%0.10%
      linear regression1.00%1.00%1.00%
      Total error1.50%
    Tools

    Get Citation

    Copy Citation Text

    Yuan Lv, Mingyu Cong, Yini Zhao, Kaiqing Niu, Ziwei Lu. Research on real-time absolute radiometric calibration technology of infrared cameras[J]. Infrared and Laser Engineering, 2022, 51(7): 20220395

    Download Citation

    EndNote(RIS)BibTexPlain Text