Photonics Research, Volume. 11, Issue 1, 55(2023)
High-fluence relay-based disposable photoacoustic-ultrasonic endoscopy for
Fig. 1. ECF-based optical waveguide strategy of endoscopic PAEM system. (a) Schematic diagram and photo of ECF; 0.25 pitch (
Fig. 2. Collinear designed PAEM-US mini-probe. (a) Schematic diagram of intra-instrument channel workable, PA, and US dual-mode imaging. (b) Schematic of PAEM-US probe with main integrated components. Inset, the section view. UT, ultrasonic transducer; TC, torque coil; S1, S2, sections 1 and 2; IW, imaging window; SG, sapphire glass; TRP, total reflection prism; SCF, single mode fiber. OC, optical channel; CC, cable channel. (c) Photograph of the fabricated PAEM-US endoscope; SUS, stainless steel. (d) Photograph of the mini-probe combined with upper electronic endoscope (2.8 mm ID channel). (e) PA lateral resolution. (f) US axial resolution. (g) Pulse response and frequency spectrum of the transducer. Fc, center frequency; BW, bandwidth.
Fig. 3. Simulation and test of prime relay. (a) Schematic of SCF-based and ECF-based optical reshaping. (b) Simulated
Fig. 4. Prototypic disposable PAEM-US catheter and PAEM-PIU. (a) Diagram of PAEM-PIU. F-interface, female interface; M-interface, male interface; ESR, electrical slip ring; L, Luer connector. (b) Full view of the whole PAEM catheter. (c) Connection of the catheter and PIU. Inset, caps used to house the SC-type OPC and electrical pinholes. SC, shell connector; RC, retracement connector; EC, electrical connector; OC, optical connector.
Fig. 5. ECF-based coupling relay for ORC and OPC. (a) Schematic of the output laser beam of SCF and ECF. (b) 2D spot profile of SCF and ECF at the axial distance
Fig. 6.
Fig. 7. PA depth-tomography results of rat colorectum. (a) Photograph of the rat colorectum imaging experiment. (b) Relative-depth encoded image with whole PA data. (c) Different depth of MAP view. (d) Statistics of vessel diameter and curvature as a function of depth. (e) Statistics of the number of vascular crossings and porosity as a function of depth.
|
|
|
Get Citation
Copy Citation Text
Xue Wen, Peng Lei, Shengxin Huang, Xiaoyu Chen, Yanchi Yuan, Di Ke, Rui Liu, Jiaxi Liang, Erqi Wang, Bo Wei, Kedi Xiong, Sihua Yang, "High-fluence relay-based disposable photoacoustic-ultrasonic endoscopy for
Category: Imaging Systems, Microscopy, and Displays
Received: Jul. 21, 2022
Accepted: Sep. 29, 2022
Published Online: Dec. 16, 2022
The Author Email: Bo Wei (weibo3@mail.sysu.edu.cn), Kedi Xiong (xiongkd2012@163.com), Sihua Yang (yangsh@scnu.edu.cn)