Acta Optica Sinica, Volume. 34, Issue 4, 411001(2014)
Multiple Imaging Method of Optical Synthetic Aperture System with Phase Error Limits Improved
[1] [1] James E Harvey, Christ Ftaclas. Field-of-view limitations of phased telescope arrays [J]. Appl Opt, 1995, 34(25): 5787-5798.
[2] [2] E E Sabatke, H B James, P Hinz. Optical design of interferometric telescopes with wide field of view [J]. Appl Opt, 2006, 45(31): 8026-8035.
[3] [3] Soon-Jo Chung, David W Miller, Olivier L de Weck. Design and implementation of sparse aperture imaging systems [C]. SPIE, 2002, 4849: 181-192.
[4] [4] R D Fiete, T A Tantalo, J R Calus, et al.. Image quality of sparse-aperture designs for remote sensing [J]. Opt Eng, 2002, 41(8): 1957-1969.
[5] [5] Wang Xiaohua, Zheng Yi, Shen Feng, et al.. Research on detection and adaptive correction of phase errors for coherent combing laser arrays [J]. Laser & Optoelectronics Progress, 2012, 49(2): 021401.
[6] [6] Wang Shengqian, Rao Changhui, Jiang Wenhan. Diffraction-limited performance and aberration tolerance of a sparse optical synthetic aperture imaging system with four sub-apertures [J]. Journal of Mordern Optics, 2008, 55(11): 1771-1785.
[7] [7] R R Butts. Effects of pistonand tilt errors on the performance of multiple mirror telescopes [C]. SPIE, 1981, 293: 85-89.
[8] [8] Jiang Yanchao, Wang Zhile, Zhao Ming, et al.. MTF-based research on the minimum fill factor in optical sparse aperture system [C]. Fourth International Conference on Intelligent Computation Technology and Automation, 2011, 612-615.
[9] [9] Wu Pengfei, Xu Qingshan, Fang Shuai, et al.. Optical model of image degradation in atmospheric inhomogeneous path [J]. Acta Optica Sinica, 2012, 32(5): 0501002.
[10] [10] Wang Dayong, Han Ji, Liu Hancheng. Imaging of optical sparse aperture systems and evaluate method [J]. Acta Photonica Sinica, 2008, 37(6): 1208-1212.
[11] [11] Chen Yiwei, Wang Fei, Wang Gaowen, et al.. New sub-aperture stitching algorithm based on transformation [J]. Acta Optica Sinica, 2013, 33(9): 0912004.
[12] [12] Wei Xiaofeng, Geng Zexun, Lou Bo, et al.. Multi-frame synthetic aperture image restoration based on array rotation [J]. J Optoelectronics·Laser, 2013, 24(4): 820-825.
Get Citation
Copy Citation Text
Wei Xiaofeng, Geng Zexun, Shen Chen, Xu Kun, Pan Yingfeng. Multiple Imaging Method of Optical Synthetic Aperture System with Phase Error Limits Improved[J]. Acta Optica Sinica, 2014, 34(4): 411001
Category: Imaging Systems
Received: Nov. 28, 2013
Accepted: --
Published Online: Mar. 25, 2014
The Author Email: Xiaofeng Wei (wxf198861@163.com)