Collection Of theses on high power laser and plasma physics, Volume. 13, Issue 1, 6632(2015)
Visualization of the influence of the air conditioning system to the high-power laser beam quality with the modulation coherent imaging method
[1] [1] C. A. Haynam, P. J. Wegner, J. M. Auerbach, M. W. Bowers, S. N. Dixit, G. V. Erbert, G. M. Heestand, M. A. Henesian, M. R. Hermann, K. S. Jancaitis, K. R. Manes, C. D. Marshall, N. C. Mehta, J. Menapace, E. Moses, J. R. Murray, M. C. Nostrand, C. D. Orth, R. Patterson, R. A. Sacks, M. J. Shaw, M. Spaeth, S. B. Sutton, W. H. Williams, C. C. Widmayer, R. K. White, S. T. Yang, and B. M. Van Wonterghem, “National Ignition Facility laser performance status,” Appl. Opt. 46, 3276–3303 (2007).
[2] [2] W. H. Williams, J. M. Auerbach, M. A. Henesian, J. K. Lawson, J. T. Hunt, R. A. Sacks, and C. C. Widmayer, “Modeling characterization of the National Ignition Facility focal spot,” Proc. SPIE 3264, 93–104 (1998).
[3] [3] D. Homoelle, M. W. Bowers, T. Budge, C. Haynam, J. Heebner, M. Hermann, K. Jancaitis, J. Jarboe, K. LaFortune, J. T. Salmon, T. Schindler, and M. Shaw, “Measurement of the repeatability of the prompt flashlamp-induced wavefront aberration on beamlines at the National Ignition Facility,” Appl. Opt. 50, 4382–4388 (2011).
[4] [4] S. B. Sutton, C. D. Marshall, C. S. Petty, L. K. Smith, B. M. Van Wonterghem, and S. Mills, “Thermal recovery of NIF amplifiers,” Proc. SPIE 3047, 560–570 (1996).
[5] [5] C. R. Wolfe and J. K. Lawson, “The measurement and analysis of wavefront structure from large aperture ICF optics,” Proc. SPIE 2633, 361–385 (1995).
[6] [6] D. J. Trummer, R. J. Foley, and G. S. Shaw, “Stability of optical elements in the NIF target area building,” Proc. SPIE 3492, 363–371 (1999).
[7] [7] M. L. Spaeth, K. R. Manes, C. C. Widmayer, W. H. Williams, P. K. Whitman, M. A. Henesian, I. F. Stowers, and J. Honig, “National Ignition Facility wavefront requirements and optical architecture,” Opt. Eng. 43, 2854–2865 (2004).
[8] [8] W. Jiang and H. Li, “Hartmann–Shack wavefront sensing and control algorithm,” Proc. SPIE 1271, 82–93 (1990).
[9] [9] G. Cao and X. Yu, “Accuracy analysis of a Hartmann–Shack wavefront sensor operated with a faint object,” Opt. Eng. 33, 2331–2335 (1994).
[10] [10] V. Y. Zavalova and A. V. Kudryashov, “Shack–Hartmann wave-front sensor for laser beam analyses,” Proc. SPIE 4493, 277–284 (2002).
[11] [11] S. Sato, T. Mori, Y. Higashi, S. Haya, M. Otsuka, and H. Yamamoto, “A profilometer for synchrotron radiation mirrors,” J. Electron Spectrosc. Relat. Phenom. 80, 481–484 (1996).
[12] [12] X. Liu, Y. Gao, and M. Chang, “A partial differential equation algorithm for wavefront reconstruction in lateral shearing interferometry,” J. Opt. A 11, 045702 (2009).
[13] [13] R. A. Zacharias, N. R. Beer, E. S. Bliss, S. C. Burkhart, S. J. Cohen, S. B. Sutton, R. L. Van Atta, S. E. Winters, J. T. Salmon, M. R. Latta, C. J. Stolz, D. C. Pigg, and T. J. Arnold, “Alignment and wavefront control systems of the National Ignition Facility,” Opt. Eng. 43, 2873–2884 (2004).
[14] [14] H. Wang, C. Liu, X. He, X. Pan, S. Zhou, R. Wu, and J. Zhu, “Wavefront measurement techniques used in high power lasers,” High Power Laser Sci. Eng. 2, e25 (2014).
[15] [15] F. Zhang and J. M. Rodenburg, “Phase retrieval based on wave-front relay and modulation,” Phys. Rev. B 82, 121104 (2010).
[16] [16] F. Zhang, I. Peterson, J. Vila-Comamala, A. Diaz, F. Berenguer, R. Bean, B. Chen, A. Menzel, I. K. Robinson, and J. M. Rodenburg, “Translation position determination in ptychographic coherent diffraction imaging,” Opt. Express 21, 13592–13606 (2013).
[17] [17] H. Tao, S. P. Veetil, J. Cheng, X. Pan, H. Wang, C. Liu, and J. Zhu, “Measurement of the complex transmittance of large optical elements with modulation coherent imaging,” Appl. Opt. 54, 1776–1781 (2015).
[18] [18] X. Pan, S. P. Veetil, C. Liu, Q. Lin, and J. Zhu, “High-contrast imaging for weakly diffracting specimens in coherent diffraction imaging,” Chin. Opt. Lett. 11, 021103 (2013).
[19] [19] S.-W. Bahk, J. Bromage, I. A. Begishev, C. Mileham, C. Stoeckl, M. Storm, and J. D. Zuegel, “On-shot focal-spot characterization technique using phase retrieval,” Appl. Opt. 47, 4589–4597 (2008).
[20] [20] S. Matsuoka and K. Yamakawa, “Wave-front measurements of terawatt-class ultrashort laser pulses by the Fresnel phase-retrieval method,” J. Opt. Soc. Am. B 17, 663–667 (2000).
[21] [21] B. E. Kruschwitz, S.-W. Bahk, J. Bromage, M. D. Moore, and D. Irwin, “Accurate target-plane focal-spot characterization in high-energy laser systems using phase retrieval,” Opt. Express 20, 20874–20883 (2012).
[22] [22] J. M. Rodenburg and H. M. Faulkner, “A phase retrieval algorithm for shifting illumination,” Appl. Phys. Lett. 85, 4795–4797 (2004).
[23] [23] H. M. L. Faulkner and J. M. Rodenburg, “Movable aperture lensless transmission microscopy: a novel phase retrieval algorithm,” Phys. Rev. Lett. 93, 023903 (2004).
[24] [24] A. M. Maiden and J. M. Rodenburg, “An improved ptychographical phase retrieval algorithm for diffractive imaging,” Ultramicroscopy 109, 1256–1262 (2009).
Get Citation
Copy Citation Text
HUA TAO, SUHAS P. VEETIL, XINGCHEN PAN, CHENG LIU, JIANQIANG ZHU. Visualization of the influence of the air conditioning system to the high-power laser beam quality with the modulation coherent imaging method[J]. Collection Of theses on high power laser and plasma physics, 2015, 13(1): 6632
Category:
Received: May. 4, 2015
Accepted: --
Published Online: May. 27, 2017
The Author Email: LIU CHENG (cheng.liu@hotmail.co.uk)