Acta Optica Sinica, Volume. 41, Issue 10, 1036001(2021)
A Miniaturized Adaptive Dual-Comb Based on Piezoelectric Transducer and Multi-stage Temperature Feedback
Fig. 2. Output characteristics and supercontinuum of two pulsed lasers. (a) Spectrum of oscillator A; (b) pulse width after two-stage amplification of pulsed laser A; (c) supercontinuum of pulsed laser A; (d) spectrum of oscillator B; (e) pulse width after two-stage amplification of pulsed laser B; (f) supercontinuum of pulsed laser B
Fig. 3. Relationships of repetition frequency with voltage and temperature. (a) Relationship between VPZT variation (ΔVPZT) and repetition frequency variation (Δf) of pulsed laser; (b) relationship between the temperature variation (ΔT) of top TEC and bottom TEC and frequency variation of pulsed laser
Fig. 5. Each parameter change in the feedback process. (a) PZT voltage changed with beat signal; (b) the first temperature feedback changed with PZT voltage
Fig. 6. Experimental results and picture of miniaturized adaptive dual-comb. (a) Change relationship between beat signal 50 B and time; (b) change relationship between repetition frequency of oscillator B and time; (c) photo of miniaturized adaptive dual-comb
Get Citation
Copy Citation Text
Xu Chen, Xiangyu Jin, Qingting Wang, Shiyu Lu, Qiang Hao, Jie Wang, Hongyu Nie, Ming Yan, Kangwen Yang, Heping Zeng. A Miniaturized Adaptive Dual-Comb Based on Piezoelectric Transducer and Multi-stage Temperature Feedback[J]. Acta Optica Sinica, 2021, 41(10): 1036001
Category: Letters
Received: Jan. 14, 2021
Accepted: Mar. 10, 2021
Published Online: May. 8, 2021
The Author Email: Yang Kangwen (kangwenyang@yeah.net)