Chinese Journal of Lasers, Volume. 40, Issue 8, 804001(2013)

Full Range Optical Coherence Tomography without Additional Group Delay Based on Spatial Interferograms Modulation

Hong Wei*, Ding Zhihua, and Yan Yangzhi
Author Affiliations
  • [in Chinese]
  • show less
    References(12)

    [2] [2] Wang Ling, Ding Zhihua, Shi Guohua, et al.. Fiber-based optical coherence tomography imaging system with rapid scanning optical delay line as phase modulator[J]. Chinese J Laser, 2008, 35(3): 472-476.

    [3] [3] Yang Liu, Hong wei, Wang Chuan, et al.. Flow measurement based on speckle in optical coherence tomography[J]. Chinese J Laser, 2012, 39(5): 0504002.

    [5] [5] Yang Liu, Wang Chuan, Ding Zhihua, et al.. Image reconstruction in dioptric media for spectral domain optical coherence tomography[J]. Chinese J Laser, 2011, 38(5): 0504001.

    [6] [6] R Leitgeb, C Hitzenberger, A Fercher. Performance of Fourier domain versus time domain optical coherence tomography[J]. Opt Express, 2003, 11(8): 889-894.

    [7] [7] M Wojtkowski, T Bajraszewski, P Targowski, et al.. Real-time in vivo imaging by high-speed spectral optical coherence tomography[J]. Opt Lett, 2003, 28(19): 1745-1747.

    [8] [8] M Wojtkowski, A Kowalczyk, R Leitgeb, et al.. Full range complex spectral optical coherence tomography technique in eye imaging[J], Opt Lett, 2002, 27(16): 1415-1417.

    [9] [9] Y Yasuno, S Makita, T Endo, et al.. Simultaneous B-M mode scanning method for real time full range Fourier domain optical coherence tomography[J]. Appl Opt, 2006, 45(8): 1861-1865.

    [10] [10] A V Zvyagin, E D J Smith, D D Sampson. Delay and dispersion characteristics of a frequency-domain optical delay line for scanning interferometry[J]. J Opt Soc Am A, 2003, 20(2): 333-341.

    [11] [11] Wang Kai, Ding Zhihua, Zeng Yan, et al.. Sinusoidal B-M method based spectral domain optical coherence tomography for the elimination of complex-conjugate artifact[J]. Opt Express, 2009, 17(19): 16820-16833.

    [12] [12] Dong Jingtao, Lu Rongsheng. Dispersion compensation based on frequency domain analysis in optical coherence microscopy[J]. Chinese J Laser, 2012, 39(1): 0116003.

    CLP Journals

    [1] Li Pei, Gao Wanrong, Chen Chaoliang. Cross-Correlation Method for Measuring Spatial Transverse Flow Rate Based on Spectral Domain Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2015, 42(10): 1004002

    Tools

    Get Citation

    Copy Citation Text

    Hong Wei, Ding Zhihua, Yan Yangzhi. Full Range Optical Coherence Tomography without Additional Group Delay Based on Spatial Interferograms Modulation[J]. Chinese Journal of Lasers, 2013, 40(8): 804001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: biomedical photonics and laser medicine

    Received: Jan. 25, 2013

    Accepted: --

    Published Online: Jul. 9, 2013

    The Author Email: Wei Hong (zjuweihong@gmail.com)

    DOI:10.3788/cjl201340.0804001

    Topics