Chinese Journal of Lasers, Volume. 37, Issue 3, 696(2010)
Near Infrared Polarimeter Based on Liquid Crystal Variable Retardes
[2] [2] Cao Wenda,C. J. Denker,Wang Haimin et al.. Characteristic evaluation of a near-infrared Fabry-Perot filter for the infrared imaging magnetograph (IRIM)[C]. SPIE,2004,5171:307-315
[3] [3] J. Wagner,T. R. Rimmele,S. Keil et al.. Advanced technology solar telescope:a progress report[C]. SPIE,6267:626709
[4] [4] Ai Guoxiang,Hu Yuefeng. The KD*P modulator in the solar magnetic field telescope[J]. Publications of the Beijing Astronomical Observatory,1986,8:86-97
[5] [5] E. A. West. Extending the field of view of KD*P electrooptic modulators[J]. Appl. Opt.,1978,17(18):3010-3013
[6] [6] L. J. November,L. M. Wilkins. Liquid crystal polarimeter:a solid state image for solar vector magnetic fields[J]. Opt. Engng.,1995,34(6):1659-1668
[7] [7] D. L. Mickey,R. C Canfield,B. J. Labonte et al.. The imaging vector magnetograph at haleakala[J]. Solar Physics,1996,168(2):229-250
[8] [8] T. Horn,A. Hofmann. Liquid crystal imaging stokes polarimeter[C]. Third Advances in Solar Physics Euroconference:Magnetic Fields and Oscillations,ASP Conference Series,1999,184:33-37
[9] [9] A. Hofmann. Liquid-crystal-based Stokes polarimeter[C]. SPIE,2000,4133:44-54
[10] [10] T. J. Spirock,C. Denker,J. Varsik et al.. Results from the big bear solar observatory′s new digital vector magnetograph[C]. American Geophysical Union,Spring Meeting,2001
[11] [11] H. Lin,J. R. Kuhn,R. Coulter. Coronal magnetic field measurements[J]. The Astrophysical Journal,2004,613:L177-L180
[12] [12] S. Jakob. SST polarization model and polarimeter calibration[D]. Master Thesis,2005,Stockholm Observatory
[13] [13] V. M. Pillet,M. Collados,J. Sánchez Almeida et al.. LPSP & TIP:full Stokes polarimeters for the canary islands[C]. ASP Conference Series,1999,18:264-272
[14] [14] M. Collados. High resolution spectropolarimetry and magnetography[C]. ASP Conference Series,1999,184:3-22
[15] [15] A. M. Gandorfer,H. P. Povel. First observations with a new imaging polarimeter[J]. Astronomy and Astrophysics,1997,328:381-389
[16] [16] Xu Chenglin,Qu Zhongquan,Zhang Xiaoyu et al.. Polarimeter with two ferroelectric liquid-crystal modulators attached to the Yunnan solar tower[J]. Appl. Opt.,2006,45(33):8428-8433
Get Citation
Copy Citation Text
Zhang Zhiyong, Deng Yuanyong, Wang Dongguang, Sun Yingzi, Xuan Weijia. Near Infrared Polarimeter Based on Liquid Crystal Variable Retardes[J]. Chinese Journal of Lasers, 2010, 37(3): 696
Category:
Received: Apr. 17, 2009
Accepted: --
Published Online: Mar. 11, 2010
The Author Email: Zhiyong Zhang (polarimetry@163.com)