Laser & Optoelectronics Progress, Volume. 49, Issue 7, 70002(2012)
Developments of X-Ray Grating Imaging Based on Talbot Interferometry
[1] [1] A. Authier. Dynamical Theory of X-Ray Diffraction[M]. New York: Oxford University Press, 2001
[2] [2] A. Momose. Recent advances in X-ray phase imaging[J]. Jpn. J. Appl. Phys., 2005, 44(9A): 6355~6367
[6] [6] Wang Zhentian. Research on Grating-Based Imaging Method and Technique with Conventional X-Ray Tube[D]. Beijing: Tsinghua University, 2010
[7] [7] C. David, B. Nohammer, H. H. Solak et al.. Differential X-ray phase contrast imaging using a shearing interferometer[J]. Appl. Phys. Lett., 2002, 81(17): 3287~3289
[8] [8] A. Momose, S. Kawamoto, I. Koyama et al.. Demonstration of X-ray Talbot interferometry[J]. Jpn. J. Appl. Phys., 2003, 42(7B): 866~868
[9] [9] Y. Takeda, W. Yashiro, Y. Suzuki et al.. X-ray phase imaging with single phase grating[J]. Jpn. J. Appl. Phys., 2007, 46(3): L89~L91
[10] [10] T. Weitkamp, A. Diaz, C. David et al.. X-ray phase imaging with a grating interferometer[J]. Opt. Express, 2005, 13(16): 6296~6304
[11] [11] F. Pfeiffer, O. Bunk, C. Schulze-Briese et al.. Shearing interferometer for quantifying the coherence of hard X-ray beams[J]. Phys. Rev. Lett., 2005, 94(16): 164801
[12] [12] T. Weitkamp, B. Nohammer, A. Diaz et al.. X-ray wavefront analysis and optics characterization with a grating interferometer[J]. Appl. Phys. Lett., 2005, 86(5): 054101
[13] [13] F. Pfeiffer, T. Weitkamp, O. Bunk et al.. Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources[J]. Nature Phys., 2006, 2(4): 258~261
[14] [14] F. Pfeiffer, M. Bech, O. Bunk et al.. Hard-X-ray dark-field imaging using a grating interferometer[J]. Nature Mater., 2008, 7(2): 134~137
[15] [15] Zhili Wang, Kun Gao, Peiping Zhu et al.. Grating-based X-ray phase contrast imaging using polychromatic laboratory sources[J]. J. Electron Spectroscopy and Related Phenomena, 2011, 184(3-6): 342~345
[16] [16] P. C. Diemoz, P. Coan, I. Zanette et al.. A simplified approach for computed tomography with an X-ray grating interferometer[J]. Opt. Express, 2011, 19(3): 1691~1698
[17] [17] Liu Xin, Guo Jinchuan, Niu Hanben. New method of detecting interferogram in differential phase-contrast imaging system based on special structured X-ray scintillator screen[J]. Chinese Physics B, 2010, 19(7): 070101
[18] [18] Huang Zhifeng, Kang Kejun, Zhang Li et al.. Alternative method for differential phase-contrast imaging with weakly coherent hard X-rays[J]. Phys. Rev. A, 2009, 79(1): 013815
[20] [20] Guanghong Chen, Joseph Zambelli, Ke Li et al.. Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography[J]. Med. Phys. Lett., 2011, 38(2): 584~588
[21] [21] Michael Chabior, Tilman Donath, Christian David et al.. Beam hardening effects in grating-based X-ray phase-contrast imaging[J]. Med. Phys., 2011, 38(3): 1189~1195
[22] [22] Thomas Weber, Peter Bart, Florian Bayer et al.. Noise in X-ray grating-based phase-contrast imaging[J]. Med. Phys., 2011, 38(7): 4133~4140
[23] [23] Martin Bech, Torben H. Jensen, Oliver Bunk et al.. Advanced contrast modalities for X-ray radiology: phase-contrast and dark-field imaging using a grating interferometer[J]. I. Med. Phys., 2010, 20(1): 7~16
[25] [25] Wang Junqiao, Zhang Xinzheng, Sun Liping et al.. Laser-induced deposition of silver nanoparticles films and microstructures onto glass substrates[J]. Chinese J. Lasers, 2011, 38(1): 0107001
[26] [26] Tilman Donath, Michael Chabior, Franz Pfeiffer et al.. Inverse geometry for grating-based X-ray phase-contrast imaging[J]. J. Appl. Phys., 2009, 106(5): 054703
[27] [27] Zhifeng Huang, Zhiqiang Chen, Li Zhang et al.. Large phase-stepping approach for high resolution hard X-ray grating-based multiple information imaging[J]. Opt. Express, 2010, 18(10): 10222~10229
[28] [28] Torben Haugaard Jensen, Martin Bech. Directional X-ray dark-field imaging of strongly ordered systems[J]. Phys. Rev. B, 2010, 82(21): 214103
[29] [29] I. Zanette, M. Bech, F. Pfeiffer et al.. Interlaced phase stepping in phase-contrast X-ray tomography[J]. Appl. Phys. Lett., 2011, 98(9): 094101
[30] [30] T. Thuering, P. Modregger, T. Grund et al.. High resolution, large field of view X-ray differential phase contrast imaging on a compact setup[J]. Appl. Phys. Lett., 2011, 99(4): 041111
[31] [31] Hidenosuke Itoh, Kentaro Nagai, Genta Sato et al.. Two-dimensional grating-based X-ray phase-contrast imaging using Fourier transform phase retrieval[J]. Opt. Express, 2011, 19(4): 3339~3346
[32] [32] X. Ge, Z. Wang, K. Gao et al.. Investigation of the partially coherent effects in a 2D Talbot interferometer[J]. Anal. Bioanal. Chem., 2011, 401(3): 865~870
[33] [33] Julien Rizzi, Timm Weitkamp, Nicolas Guérineau et al.. Quadriwave lateral shearing interferometry in an achromatic and continuously self-imaging regime for future X-ray phase imaging[J]. Opt. Lett., 2011, 36(8): 1398~1400
[34] [34] Takashi Nakamura, Chang Chang. Quantitative X-ray differential-interference-contrast microscopy with independently adjustable bias and shear[J]. Phys. Rev. A, 2011, 83(4): 043808
[35] [35] Atsushi Momose, Wataru Yashiro, Sébastien Harasse et al.. Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm[J]. Opt. Express, 2011, 19(9): 8423~8432
Get Citation
Copy Citation Text
Han Yueping, Chen Zhiqiang, Zhang Li, Huang Zhifeng, Zhang Ran, Jiang Xiaolei. Developments of X-Ray Grating Imaging Based on Talbot Interferometry[J]. Laser & Optoelectronics Progress, 2012, 49(7): 70002
Category: Reviews
Received: Dec. 29, 2011
Accepted: --
Published Online: May. 2, 2012
The Author Email: Yueping Han (yuepinghan@163.com)