Photonic Sensors, Volume. 7, Issue 3, 253(2017)

Development of High Sensitivity Eight-Element Multiplexed Fiber Laser Acoustic Pressure Hydrophone Array and Interrogation System

Ming LI1,2, Zhihui SUN2, Xiaolei ZHANG2, Shujuan LI2, Zhiqiang SONG2, Meng WANG2, Jian GUO2, Jiasheng NI2, Chang WANG2、*, Gangding PENG3, and Xiangang XU1
Author Affiliations
  • 1State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, China
  • 2Jinan Research Center, Laser Institute of Shandong Academy of Sciences, Jinan, 250014, China
  • 3School of Electronic Engineering and Telecommunication, University of New South Wales, Sydney, 2052, Austrilia
  • show less
    References(14)

    [1] [1] Y. L’eguillon, K. H. Tow, P. Besnard, A. Mugnier, D. Pureur, and M. Doisy, “First demonstration of a 12 DFB fiber laser array on a 100 GHz ITU grid for underwater acoustic sensing application,” in Proceeding of SPIE Conference on Optical Sensing and Detection II, Brussels, Belgium, 2012, pp. 17.

    [2] [2] S. Foster, A. Tikhomirov, J. Harrison, and J. V. Velzen, “Field demonstration of an 8-element fibre laser hydrophone array,” in Proceeding of 23rd International Conference on Optical Fibre Sensors, Santander, Spain, 2014, pp. 91570H–1 –91570H–4.

    [3] [3] F. X. Launay, R. Bouffaron, R. Lardat, G. Roux, M. Doisy, and C. Bergogne, “Acoustic antenna based on fiber laser hydrophones,” in Proceeding of 23rd International Conference on Optical Fibre Sensors, Santander, Spain, 2014, pp. 91570Y–1 –91570Y–4.

    [4] [4] Q. Zhu, X. B. Chen, J. P. Chen, and G. D. Peng, “DFB fiber laser fabrication by moving phase mask,” Optical Fiber & Electric Cable & Their Applications, 2006, 1(1): 17–20.

    [5] [5] B. Tan and J. B. Huang, “Design about a novel encapsulation structure of DFB fiber laser hydrophones,” in Proceeding of International Symposium on Photonics and Optoelectronics, Suzhou, China, 2014, pp. 92330X–1–92330X–7.

    [6] [6] L. N. Ma, “Fiber laser hydrophone,” Ph.D. dissertation, National University of Defense Technology, Changsha, 2010.

    [7] [7] W. T. Zhang, Y. L. Liu, F. Li, and H. Xiao, “Fiber laser hydrophone based on double diaphragms: theory and experiment,” Journal of Lightwave Technology, 2008, 26(10): 1349–1352.

    [8] [8] W. T. Zhang, F. Li, and Y. L. Liu, “Field test of an eight-element fiber laser hydrophone array,” in Proceeding of 22nd International Conference on Optical Fiber Sensors, Beijing, China, 2012, pp. 8421AX–1–8421AX–4.

    [9] [9] H. C. Gu, J. B. Huang, H. B. Yu, R. Z. Li, B. Tang, and J. Wu, “A 4-element fiber laser hydrophone towed linear array,” in Proceeding of International Symposium on Optoelectronic Technology and Application (IPTA)-Laser and Optical Measurement Technology and Fiber Optic Sensors, Beijing, China, 2014, pp. 92972Y–1 –92972Y–6.

    [10] [10] S. W. Lovseth and E. Ronnekleiv, “Fundamental and higher order mode thresholds of DFB fiber lasers,” Journal of Lightwave Technology, 2002, 20(3): 494–501.

    [11] [11] D. Sacastru, S. Miclos, and I. Lancranjan, “Theoptical analysis of the output noise of a FDB fiber laser sensor,” International Journal of Mathematics & Computers in Simulation, 2010, 4(4): 116–123.

    [12] [12] Z. Q. Song, H. F. Qi, C. Wang, Y. Shang, and W. Chang, “Narrow line-width fiber laser and application in sensing,” Acta Optica Sinica, 2015, 35(s2): s214005.

    [13] [13] H. Xu, C. Wang, G. D. Peng, X. L. Zhang, Y. Y. Ying, Z. H. Sun, et al., “A distributed feedback fiber laser hydrophone with high sensitivity and flat frenquency response,” Shandong Science, 2013, 26(4): 46–50.

    [14] [14] Y. Chen, J. Zhang, M. Zhang, and L. W. Wang, “Calibration of phase-shifted sensitivity of optical fiber hydrophone in the frequency range 20 Hz to 10 kHz,” Acta Optica Sinica, 2011, 40(11): 1686–1691.

    Tools

    Get Citation

    Copy Citation Text

    Ming LI, Zhihui SUN, Xiaolei ZHANG, Shujuan LI, Zhiqiang SONG, Meng WANG, Jian GUO, Jiasheng NI, Chang WANG, Gangding PENG, Xiangang XU. Development of High Sensitivity Eight-Element Multiplexed Fiber Laser Acoustic Pressure Hydrophone Array and Interrogation System[J]. Photonic Sensors, 2017, 7(3): 253

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Regular

    Received: Apr. 19, 2017

    Accepted: Jun. 5, 2017

    Published Online: Dec. 4, 2017

    The Author Email: WANG Chang (ch_wangs@163.com)

    DOI:10.1007/s13320-017-0426-0

    Topics