Stringent specifications for next-generation non-volatile memory devices have been imposed to overcome the ultimate limits of device physics and concomitant manufacturing technologies of conventional Si-based electronics[
Journal of Semiconductors, Volume. 42, Issue 1, 014103(2021)
Neutron irradiation-induced effects on the reliability performance of electrochemical metallization memory devices
In this work, electrochemical metallization memory (ECM) devices with an Ag/AgInSbTe (AIST)/amorphous carbon (a-C)/Pt structure were irradiated with 14 MeV neutrons. The switching reliability performance before and after neutron irradiation was compared and analyzed in detail. The results show that the irradiated memory cells functioned properly, and the initial resistance, the resistance at the low-resistance state (LRS), the RESET voltage and the data retention performance showed little degradation even when the total neutron fluence was as high as 2.5 × 1011 n/cm2. Other switching characteristics such as the forming voltage, the resistance at the high-resistance state (HRS), and the SET voltage were also studied, all of which merely showed a slight parameter drift. Irradiation-induced Ag ions doping of the a-C layer is proposed to explain the damaging effects of neutron irradiation. The excellent hard characteristics of these Ag/AIST/a-C/Pt-based ECM devices suggest potential beneficial applications in the aerospace and nuclear industries.
1. Introduction
Stringent specifications for next-generation non-volatile memory devices have been imposed to overcome the ultimate limits of device physics and concomitant manufacturing technologies of conventional Si-based electronics[
Previous work on the characteristics of irradiation-hardened resistive switching memory devices is mostly based on gamma-ray radiation[
Our previous work had systematically evaluated the performance of Ag/AgInSbTe (AIST)/amorphous carbon (a-C)/Pt-based ECM devices. These devices show excellent resistive switching uniformity and good cycling endurance[
2. Experimental section
Various ECM devices, each with an Ag/AIST/a-C/Pt structure [Fig. 1(a)] were fabricated. The depositions of the a-C layer and the AIST layer were done by RF magnetron sputtering of pure graphite and AIST (1 : 1 : 1 : 1) targets at room temperature. The thicknesses of the a-C and AIST layers were 20 and 15 nm, respectively. Finally, the top electrode metal Ag (50 nm) was thermally evaporated and patterned using a shadow mask with a diameter of 200 µm. In addition, these fabricated devices were mounted and wire bonded into ceramic dual in-line packages [see Fig. 1(b)]. The neutron irradiation experiments were conducted at the Institute of Radiation Technology of Northeast Normal University. For guaranteeing the working lifetime of our penning ion source neutron tube, the yield of the neutron tube was adjusted to ~ 5 × 108 n/s. To achieve a series of different neutron fluences [see Fig. 1(c)], three packaged Ag/AIST/a-C/Pt devices were fastened in three different positions. These packaged memories devices were continuously irradiated for seven hours. Through simulation calculations, the total neutron fluences of the devices, here labeled D1, D2, and D3, were estimated at approximately 2.5 × 109, 2.5 × 1010, and 2.5 × 1011 n/cm2, respectively. A reference device, labeled D0, that was not irradiated by neutrons was used in comparisons with results. Then, these irradiated ECM devices were tested using a Keithley 2636A source meter. The current flow from the top to the bottom electrode is defined as the positive direction.
Figure 1.(Color online) (a) Schematic diagrams of Ag/AIST/a-C/Pt ECM device. (b) Photograph of packaged Ag/AIST/a-C/Pt ECM devices. (c) Three devices were fastened in different positions to be exposed to different neutron fluences.
3. Results and discussion
First, we measured the initial resistance (IR) for 15 randomly selected devices from the four packaged ECM devices, D0, D1, D2, and D3. We found that the IR of the ECM cells [Fig. 2(a)] had not changed significantly and remained in the range from 105 to 107 Ω. As the resistance of the Ag/AIST/a-C/Pt devices mainly depends on the conductivity of the a-C film, we therefore deduce that the characteristics had not changed and interior structure of the a-C materials had not been damaged after neutron irradiation. Our previous reports had shown that pristine Ag/AIST/a-C/Pt devices need a forming process. For the four device packages for this work, we collected the forming voltage of each tested cell [Fig. 2(b)]. Clearly, the forming voltage gradually decreases with increasing neutron fluence. The forming process for the ECM devices has three main stages: Ag oxidation, Ag ions migration, and Ag ions reduction. In general, Ag oxidation occurs readily at the interface of Ag and the chalcogenide because its activation energy is low[
Figure 2.(Color online) (a) Initial resistance and (b) forming voltage of the four types of packaged ECM devices, D0, D1, D2, and D3, respectively.
From the I–V curves taken from the four different ECM devices (Fig. 3), we see that our devices still operate normally even after being irradiated with a total neutron fluence of 2.5 × 1011 n/cm2. To prevent the tested cells from hardening, a compliance current of 0.5 mA was subsequently applied during the SET process. To observe the evolutionary trend of the resistive switching memory clearly, we measured the values of the characteristic parameters from 50 normal cycles for D0, D1, D2, and D3. The HRS resistance, for instance, decreases gradually from ~ 4 × 104 to ~ 6 × 103 Ω with increasing total neutron fluence [Fig. 4(a)], whereas the low-resistance-state (LRS) resistance remains almost unchanged. Furthermore, the SET/RESET voltages [Fig. 4(b)] show either no really obvious variation or the number of subjects is too small to yield reliable results for reference.
Figure 3.Typical
Figure 4.(Color online) (a) HRS and LRS variations and (b) SET and RESET voltage variations of the ECM devices D0, D1, D2, and D3.
To reveal the variations in the resistive switching parameters, we randomly chose 15 cells from each ECM device package to perform a comparative analysis. The cumulative spread of HRS/LRS values [Fig. 5(a)] show that the median value of the HRS resistance indeed decreases along with increasing total neutron fluence; this behavior is consistent with the conclusion from the cycle variations [Fig. 4(a)]. In addition, the cumulative probability of SET/RESET voltages [Fig. 5(b)] show that the median value of the SET voltage increases with total neutron fluence. Although the irradiated ECM devices functioned properly, the values of the HRS resistance and the SET voltage had however both changed, suggesting that neutron irradiation may have had an impact on the material properties of the ECM devices. Knowing that the neutron beam penetrability is very strong, we write the attenuation process as[
Figure 1.(Color online) (a) Schematic diagrams of Ag/AIST/a-C/Pt ECM device. (b) Photograph of packaged Ag/AIST/a-C/Pt ECM devices. (c) Three devices were fastened in different positions to be exposed to different neutron fluences.
where I0 and Iout denote the incident and transmitted beams, κ the attenuation coefficient of the material, and d the thickness of the material in the transmitted direction. With κ of the Ag top electrode being as much as 4.04, d is merely 50 nm. Thus, very few neutrons are absorbed or scattered by the top electrode during irradiation (< 0.01 %), implying that the AIST layer and the a-C layer are also irradiated with almost the same neutron fluence. The neutrons generated from our penning ion source neutron tube are almost fast neutrons (14 MeV), which on impact with atomic nuclei of the irradiated material undergo inelastic collision. According to previous reports, once irradiated, the Ag atoms spontaneously diffuse into a chalcogenide to form Ag ions[
Figure 3.Typical
Figs. 6(b)–(d) illustrate a possible mechanism that underscore the effects of neutron irradiation on resistive switching in the ECM memory devices. During the SET process [Fig. 6(c)], the redox reactions of the Ag atoms take place and induce Ag-ion migrations into the a-C layer, which then are reduced to Ag atoms on the surface of the bottom Pt electrode. With the continuous accumulation of Ag atoms, an Ag conductive filament is formed. The LRS resistance mainly depends on the characteristics of this filament rather than the insulating material (a-C layer). Therefore, the LRS resistance of each ECM device remains unchanged after neutron irradiation [Fig. 5(a)]. During the RESET process, the Ag atoms of the filament are oxidized and migrate back to the top electrode. In general, the filament ruptures at the narrowest point or at a location with maximum temperature[
From previous reports, the material characteristics of the gap determine the HRS resistance[
From the discussion above, we can see that the Ag/AIST/a-C/Pt ECM devices operate normally even during neutron beam irradiation. Aside from the resistive switching parameters, retention performance is another critical reliability issue. From the retention characteristics of both HRS and LRS for the four ECM device packages, D0–D3 (Fig. 7), the resistance values exhibit neither failure nor obvious degradation over 104 s, despite slight fluctuations in their resistance states, showing good potential retention characteristics of non-volatile storage.
Figure 4.(Color online) (a) HRS and LRS variations and (b) SET and RESET voltage variations of the ECM devices D0, D1, D2, and D3.
4. Conclusion
The 14 MeV neutron irradiation effects on the resistive switching reliability of Ag/AIST/a-C/Pt-based ECM devices were investigated. We tested initial resistance, forming voltage, DC I–V curves, HRS/LRS resistance, SET/RESET voltage, and retention performance before and after neutron irradiation at various total fluences. A slight parameter drift was observed in the forming voltage, the HRS resistance, and the SET voltage, mainly through Ag ion injection into the a-C film near the AIST/a-C interface. Our ECM devices still functioned properly, demonstrating furthermore a robust tolerance to neutron irradiation and great promise in applications in both aerospace and nuclear industries.
Acknowledgements
This work was supported by the National Natural Science Foundation of China (Nos. 11974072, 52072065, 51732003, 51872043, 51902048, 61774031, 61574031, 62004016 and U19A2091), the NSFC for Distinguished Young Scholars (No. 52025022), the 111 Project (No. B13013), the fund from Ministry Education (No. 6141A02033414), the fund from Ministry of Science and Technology of China (Nos. 2018YFE0118300, 2019YFB2205100), the fund from Education Department of Jilin Province (No. JJKH20200734KJ), Open Foundation of Key Laboratory for UV-Emitting Materials and Technology of Ministry of Education, Northeast Normal University (No. 135130013), and the Innovative Research Funds of Changchun University of Science and Technology (No. XJJLG201907).
[14] et alUnexpectedly large charge radii of neutron-rich calcium isotopes. Nat Phys, 12, 594(2016).
[20]
[23] Electron self-trapping in Ge2Se3 and its role in Ag and Sn incorporation. Mater Res Soc Symp Proc, 1431(2012).
Get Citation
Copy Citation Text
Ye Tao, Xuhong Li, Zhongqiang Wang, Gang Li, Haiyang Xu, Xiaoning Zhao, Ya Lin, Yichun Liu. Neutron irradiation-induced effects on the reliability performance of electrochemical metallization memory devices[J]. Journal of Semiconductors, 2021, 42(1): 014103
Category: Articles
Received: Oct. 14, 2020
Accepted: --
Published Online: Mar. 19, 2021
The Author Email: