Acta Optica Sinica, Volume. 42, Issue 22, 2212002(2022)

Three-Dimensional Measurement Method for Binary-Coded Fringe Focus Projection

Fei Yan1,2, Jian Qi1, Yinping Liu3, Di Wu1, and Jia Liu1,2、*
Author Affiliations
  • 1School of Automation, Nanjing University of Information Science and Technology, Nanjing 210044, Jiangsu , China
  • 2Jiangsu Provincial Collaborative Innovation Center for Atmospheric Environment and Equipment Technology, Nanjing 210044, Jiangsu , China
  • 3School of Atmospheric Physics, Nanjing University of Information Science and Technology, Nanjing 210044, Jiangsu , China
  • show less
    Figures & Tables(12)
    Principle of phase shift method
    Schematic diagram of binary fringe coding
    Schematic diagram of single cycle image processing
    Principle of wrapped phase solution. (a) Binary coded images used to generate first sinusoidal image; (b) sinusoidal and planar images generated from Fig. 4(a); (c) sinusoidal and planar images generated from Fig. 4(d); (d) binary coded images used to generate second sinusoidal image; (e) wrapped phase image; (f) section curve of wrapped phase
    Sinusoidal fringe images. (a) Projected sinusoidal fringe image; (b) sinusoidal fringe image generated by proposed method
    Reconstructed point cloud data. (a) Distance measurement; (b) measurement near focal plane; (c) close measurement
    Reconstruction results of standard ball. (a) Distance measurement; (b) measurement near focal plane; (c) close measurement
    Fitting results of sphere. (a) Fitted sphere; (b) depth distribution
    Experimental reconstruction results of calibration plate
    Reconstruction results of plaster head. (a) Overall results; (b) local magnification results
    • Table 1. Analysis results of sphere fitting error

      View table

      Table 1. Analysis results of sphere fitting error

      MethodFitted sphere diameterRMSE
      Three-step phase shift50.8140600.1165
      Twelve-step phase shift50.8140410.0725
      Proposed50.8140640.0425
    • Table 2. Analysis results of linear fitting error of calibration plate

      View table

      Table 2. Analysis results of linear fitting error of calibration plate

      MethodRMSESSE
      Three-step phase shift0.1064.456
      Twelve-step phase shift0.0832.755
      Proposed0.0852.895
    Tools

    Get Citation

    Copy Citation Text

    Fei Yan, Jian Qi, Yinping Liu, Di Wu, Jia Liu. Three-Dimensional Measurement Method for Binary-Coded Fringe Focus Projection[J]. Acta Optica Sinica, 2022, 42(22): 2212002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: May. 5, 2022

    Accepted: Jun. 4, 2022

    Published Online: Nov. 7, 2022

    The Author Email: Liu Jia (liujia@nuist.edu.cn)