NUCLEAR TECHNIQUES, Volume. 48, Issue 4, 040501(2025)
Experimental study on particle loss in horizontal straight tube of sampling system in nuclear facilities
Fig. 2. Snapshot of TSI 3321 aerodynamic particle size spectrometer
Fig. 3. Physical model of particle deposition in horizontal circular tube section
Fig. 6. Comparison of penetration test results for stainless steel pipe (D=50 mm, L=5 m)
Fig. 7. Comparison of penetration test results for carbon steel pipe (D=50 mm, L=5 m)
Fig. 8. Dimensionless relaxation time of aerosols with different particle sizes under different pipe diameters
Fig. 9. Comparison of experimental results of penetration rate of 10 μm aerosol in stainless-steel pipes at the length of 5 m and diameters of 50 mm, 110 mm respectively
Fig. 10. Comparison of experimental results of penetration rate of 2 μm, 5 μm aerosol in stainless-steel pipes at the length of 5 m and diameters of 50 mm, 110 mm respectively
|
Get Citation
Copy Citation Text
Qinxin DAI, Chenyu SHAN, Weiguo GU, Dezhong WANG, Siyuan WU, Jinpeng HE, Kang CHANG, Qingxin LEI, Baojie NIE. Experimental study on particle loss in horizontal straight tube of sampling system in nuclear facilities[J]. NUCLEAR TECHNIQUES, 2025, 48(4): 040501
Category: NUCLEAR PHYSICS, INTERDISCIPLINARY RESEARCH
Received: Aug. 7, 2024
Accepted: --
Published Online: Jun. 3, 2025
The Author Email: Weiguo GU (顾卫国)