Journal of Radiation Research and Radiation Processing, Volume. 43, Issue 3, 030601-1(2025)

A method for rapid screening of 14C in water samples from a nuclear medicine factorys decay pool and surrounding environmental water

Lixin GE1、*, Gang HAN2, and Chao ZHAO2
Author Affiliations
  • 1Shanghai Technology Center of Radiation Environmental Safety, Shanghai 200065, China
  • 2Shanghai Institute of Measurement and Test Technology, Shanghai 201203, China
  • show less
    Figures & Tables(5)
    Flow chat of 14C direct analysis method for environmental water samples
    Measured spectra of the environmental water samples (color online)
    • Table 1. Distribution of sampling location

      View table
      View in Article

      Table 1. Distribution of sampling location

      编号No.取样位置 Sampling location
      1

      雨水总排口下游河道

      River downstream of the main rainwater outlet

      2

      雨水总排口上游河道

      River upstream of the main rainwater outlet

      3雨水总排口 Rainwater main outlet
      4园区污水井 Sewage well of the park
      5衰变池采样口 Sampling port of the decay pool
      6雨水井 Rainwater well
      7衰变池一级 Decay pool level 1
      8衰变池二级 Decay pool level 2
    • Table 2. Measurement results of samples (No. 1~8)

      View table
      View in Article

      Table 2. Measurement results of samples (No. 1~8)

      编号

      No.

      样品计数率 / min-1

      Counting rate of

      sample

      内标液计数率 / min-1

      Counting rate of internal

      standard sample

      内标液活度 / Bq

      Activity of internal

      standard sample

      探测效率 / %

      Detection

      efficiency

      14C活度浓度 / (Bq∙L-1)

      14C activity concentration

      of sample

      12.24 734.0207.038.1<LLD
      22.13 673.2200.630.5<LLD
      32.34 672.8201.738.6<LLD
      462.64 588.4204.936.8342
      5290.95 095.5203.839.31 531
      69.04 558.8202.737.438
      7214.44 879.5207.037.61 178
      8237.44 783.4205.936.81 332
    • Table 3. Measurement results of validation samples

      View table
      View in Article

      Table 3. Measurement results of validation samples

      编号

      No.

      内标液活度 / Bq

      Activity of internal standard sample

      探测效率 / %

      Detection efficiency

      14C活度浓度 / (kBq∙L-1)

      14C activity concentration of sample

      参考值Reference value测量值Measured value
      V13 38236.625.925.7
      V23 51037.025.224.9
    Tools

    Get Citation

    Copy Citation Text

    Lixin GE, Gang HAN, Chao ZHAO. A method for rapid screening of 14C in water samples from a nuclear medicine factorys decay pool and surrounding environmental water[J]. Journal of Radiation Research and Radiation Processing, 2025, 43(3): 030601-1

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: RADIATION PROTECTION

    Received: Oct. 19, 2024

    Accepted: Dec. 2, 2024

    Published Online: Jul. 7, 2025

    The Author Email: Lixin GE (gelix68@126.com)

    DOI:10.11889/j.1000-3436.2024-0086

    Topics