Chinese Journal of Lasers, Volume. 40, Issue s1, 104002(2013)

Photoacoustic Imaging System Based on a Pulsed Laser Diode Excitation

Zeng Lüming1、*, Liu Guodong1, Yang Diwu2, and Ji Xuanrong3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(25)

    [1] [1] Lihong V Wang, Song Hu. Photoacoustic tomography: in vivo imaging from organelles to organs[J]. Science, 2012, 335(6075): 1458-1462.

    [2] [2] Lihong V Wang. Multiscale photoacoustic microscopy and computed tomography[J]. Nature Photon, 2009, 3(9): 503-509.

    [3] [3] Hao F Zhang, Konstantin Maslov, Lihong V Wang. In vivo imaging of subcutaneous structures using functional photoacoustic microscopy[J]. Nature Protoc, 2007, 2(4): 797-804.

    [4] [4] Hui Wang, Xiaoquan Yang, Zhen Wang, et al.. Early monitoring of cerebral hypoperfusion in rats by laser speckle imaging and functional photoacoustic microscope[J]. J Biomed Opt, 2012, 17(6): 061207.

    [5] [5] Zhifang Li, Hui Li, Zhiping Zeng, et al.. Determination of optical absorption coefficient with focusing photoacoustic imaging[J]. J Biomed Opt, 2012, 17(6): 061216.

    [6] [6] Jianhua Chen, Riqiang Lin, Huina Wang, et al.. Blind-deconvolution optical-resolution photoacoustic microscopy in vivo[J]. Opt Express, 2013, 21(6): 7316-7327.

    [7] [7] Yi Yuan, Sihua Yang, Da Xing. Optical-resolution photoacoustic microscopy based on two-dimensional scanning galvanometer[J]. Appl Phys Lett, 2012, 100(2): 023702.

    [8] [8] Lvming Zeng, Da Xing, Huaimin Gu, et al.. High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet[J]. Med Phys, 2007, 34(2): 556-563.

    [9] [9] Lvming Zeng, Da Xing, Huaimin Gu, et al.. Fast microwave-induced thermoacoustic tomography based on multi-element phase-controlled focus technique[J]. Chin Phys Lett, 2006, 23(5): 1215-1218.

    [10] [10] Diwu Yang, Lvming Zeng, Xuanrong Ji, et al.. Fast photoacoustic imaging of blood vessels based on an annular transducer array[J]. Chin Phys Lett, 2012, 29(10): 104302.

    [11] [11] Diwu Yang, Lvming Zeng, Changning Pan, et al.. Noninvasive photoacoustic detecting intraocular foreign bodies with an annular transducer array[J]. Opt Express, 2013, 21(1): 984-991.

    [12] [12] Xie Wenming, Zeng Zhiping, Li Li, et al.. Signal compensation in long-focal-zone photoacoustic imaging systems[J]. Chinese J Lasers, 2012, 39(1): 0104001.

    [13] [13] Xu Dong, Xiang Liangzhong, Ji Xuanrong. Photoacoustic imaging system based on multi-channel parallel acquisition[J]. Chinese J Lasers, 2011, 38(2): 0204002.

    [14] [14] Zeng Lvming, Liu Guodong, Ren Zhong, et al.. Design of high-resolution photoacoustic imaging system based on LabVIEW station[J]. Acta Photonica Sinica, 2008, 37(7): 1436-1440.

    [15] [15] Zhang Jian, Yang Sihua. Photoacoustic component imaging based on multi-spectral excitation[J]. Chinese J Lasers, 2011, 38(1): 0104001.

    [16] [16] K Maslov, L V Wang. Photoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser[J]. J Biomed Opt, 2008, 13(2): 024006.

    [17] [17] T J Allen, P C Beard. Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging[J]. Opt Lett, 2006, 31(23): 3462-3464.

    [18] [18] T J Allen, P C Beard. Dual wavelength laser diode excitation source for 2D photoacoustic imaging[C]. SPIE, 2007, 6437: 64371U.

    [19] [19] R Kolkman, W Steenbergen, T Leeuwen. In vivo photoacoustic imaging of blood vessels with a pulsed laser diode[J]. Lasers Med Sci, 2006, 21(3): 134-139.

    [21] [21] M P Mienkina, C S Friedrich, N C Gerhardt, et al.. Multispectral photoacoustic coded excitation imaging using unipolar orthogonal Golay codes[J]. Opt Express, 2010, 18(9): 9076-9087.

    [22] [22] S Y Su, P C Li. Coded excitation for photoacoustic imaging using a high-speed diode laser[J]. Opt Express, 2011, 19(2): 1174-1182.

    [23] [23] T J Allen, P C Beard. Light emitting diodes as an excitation source for biomedical photoacoustics[C]. SPIE, 2013, 8581: 85811F.

    [24] [24] W E Lorensen, H E Cline. Marching cubes: a high resolution 3D surface construction algorithm[J]. Computer Graphics, 1987, 21(4): 163-169.

    [25] [25] S Raman, R Wenger. Quality isosurface mesh generation using an extended marching cubes lookup table[J]. Comput Graph Forum, 2008, 27(3): 791-798.

    CLP Journals

    [1] Jiang Huilü, Liao Na, Li Chaohong, Li Yiyu, Chen Hao, Huang Jinhai, Wang Qinmei. High-Speed Compact Adaptive Optics Scanning Laser Ophthalmoscope[J]. Acta Optica Sinica, 2015, 35(11): 1117002

    [2] Wang Ling, Zhu Hailong, Tu Pei, Wu Kaihua. High-Speed Three-Dimensional Swept Source Optical Coherence Tomography System Based on LabVIEW[J]. Chinese Journal of Lasers, 2014, 41(7): 704001

    Tools

    Get Citation

    Copy Citation Text

    Zeng Lüming, Liu Guodong, Yang Diwu, Ji Xuanrong. Photoacoustic Imaging System Based on a Pulsed Laser Diode Excitation[J]. Chinese Journal of Lasers, 2013, 40(s1): 104002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: biomedical photonics and laser medicine

    Received: Aug. 1, 2013

    Accepted: --

    Published Online: Dec. 25, 2013

    The Author Email: Lüming Zeng (zenglvming@163.com)

    DOI:10.3788/cjl201340.s104002

    Topics