Chinese Journal of Lasers, Volume. 46, Issue 2, 0207001(2019)

Multi-Objective Optimization for Laser Closure Process Parameters in vitro Skin Tissue Based on NSGA-Ⅱ

Jun Huang1,2、*, Zibo Chen1, Qimeng Liu1, Cong Li1, and Kehong Wang1,2
Author Affiliations
  • 1 School of Material Science and Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China
  • 2 Key Laboratory for Controlled Arc Intelligent Material Additive Technology, Ministry of Industry Informatization, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China
  • show less
    Figures & Tables(10)
    (a) Experimental tissue sample; (b) experiment setup
    Flow chart of the NSGA-Ⅱ
    Pareto-optimal front for incision tensile strength and tissue temperature
    Appearances of in vitro pigskin tissue closure with optimized parameters. (a) Front side; (b) reverse side; (c) cross-section
    Micrograph of laser closure in vitro pigskin tissue
    • Table 1. Experimental parameters and results

      View table

      Table 1. Experimental parameters and results

      NumberPowerP /WSpeed v /(mm·s-1)FrequencyF /kHzTensile strengthσb /(N·cm-2)Peak temperatureT /℃
      13.525015038.249.2
      242005027.353.0
      331505040.250.0
      442501002853.5
      5415010036.758.0
      63.520010043.853.5
      732505037.549.0
      8315010022.142.0
      9325010027.239.8
      103.520010045.752.7
      1132005027.340.8
      123.515015028.953.3
      13420015044.756.5
      143.520010045.953.1
      153.520010042.454.5
      16320015023.640.8
      173.52001004554.2
    • Table 2. Value range of process parameters

      View table

      Table 2. Value range of process parameters

      Welding parametersValue
      P /W33.54
      v /(mm·s-1)150200250
      F /kHz50100150
    • Table 3. Pareto-optimal solution

      View table

      Table 3. Pareto-optimal solution

      NumberLaser powerP /WLaser frequencyF /kHzWelding speedv /(mm·s-1)Tensile strengthσb /(N·cm-2)Tissue temperatureT /℃
      13.65119.81205.3344.7953.29
      23.57121.41220.9744.2353.57
      33.59129.36216.5244.4253.87
    • Table 4. Sensitivity of the response of objective functions to the decision variables

      View table

      Table 4. Sensitivity of the response of objective functions to the decision variables

      ParameterRange /%Δσb /(N·cm-2)ΔTp /℃
      ΔP /W+10-10+4.1-3.2+3.5-4.5
      Δv /(mm·s-1)+10-10+3.4-3.0+0.50-0.80
      ΔF /kHz+10-10+2.1-2.4+0.6-0.4
    • Table 5. Experimental verification results

      View table

      Table 5. Experimental verification results

      Number12345Average
      σb /(N·cm-2)47.947.746.345.146.546.7
      T /℃51.252.549.348.652.450.8
    Tools

    Get Citation

    Copy Citation Text

    Jun Huang, Zibo Chen, Qimeng Liu, Cong Li, Kehong Wang. Multi-Objective Optimization for Laser Closure Process Parameters in vitro Skin Tissue Based on NSGA-Ⅱ[J]. Chinese Journal of Lasers, 2019, 46(2): 0207001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: biomedical photonics and laser medicine

    Received: Sep. 20, 2018

    Accepted: Oct. 24, 2018

    Published Online: May. 9, 2019

    The Author Email:

    DOI:10.3788/CJL201946.0207001

    Topics