Spectroscopy and Spectral Analysis, Volume. 43, Issue 3, 867(2023)

Evaluation of Long-Term Stability for Non-Standard Method and Application in Trace Element Analysis of Pure Nickel by Glow Discharge Mass Spectrometry

YANG Guo-wu1、*, HOU Yan-xia1, SUN Xiao-fei2, JIA Yun-hai1, and LI Xiao-jia1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(18)

    [2] [2] ISO 5725-2: 2019, Accuracy (Trueness and Precision) of Measurement Methods and Results-Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method. International Standard.

    [3] [3] ISO 5725-3: 1994, Accuracy (Trueness and Precision) of Measurement Methods and Results-Part 3: Intermediate Measures of the Precision of a Standard Measurement Method. International Standard.

    [4] [4] ASTM F1593-2008(2016), Standard Test Method for Trace Metallic Impurities in Electronic Grade Aluminum by High Mass-Resolution Glow-Discharge Mass Spectrometer. ASTM International.

    [5] [5] Hu F F, Wang C H, Li J D, et al. At. Spectrosc., 2021, 42(1): 25.

    [6] [6] Patricia Grinberg, Bradley A J Methven, Katarzyna Swider, et al. ACS Omega, 2021, b(35): 22717.

    [7] [7] Yang Weifeng, Zhuo Shangjun, Zhu Zhenli, et al. J. Anal. At. Spectrom., 2021, 36: 932.

    [8] [8] Gagan Paudel, Marisa Di Sabatino. J. Anal. At. Spectrom., 2020, 35: 2748.

    [9] [9] Lara Lobo, Beatriz Fernández, Marta Aranaz, et al. Spectrochimica Acta Part B, 2020, 168: 105865.

    [10] [10] Paudel G, Kasik M, Di Sabatino M. J. Anal. At. Spectrom., 2019, 34: 1829.

    [11] [11] Cristina Gonzalez-Gago, Petr Smid, Thomas Hofmann, et al. J. Anal. At. Spectrom., 2019, 34: 1109.

    [12] [12] Wei Xinjian, Qin Zhen, Xiong Penghui, et al. Spectrochimica Acta Part B, 2019, 154: 43.

    [15] [15] Kentaro Yamada, Michihisa Uemoto. Analytical Sciences, 2018, 34: 743.

    [16] [16] Fu Liang, Ma Juncai, Shi Shuyun. J. Cent. South Univ., 2018, 25: 1590.

    [18] [18] Juris Meija, Brad Methven, Ralph E Sturgeon. Metrologia, 2017, 54: 796.

    [19] [19] Wei Juan, Dong Jiangli, Zhuo Shangjun, et al. Anal. Chem., 2017, 89, 1382.

    [20] [20] Zhang Jianying, Zhou Tao, Tang Yichuan, et al. J. Anal. At. Spectrom., 2016, 31: 2182.

    [23] [23] Marisa Di Sabatino, Anne L. Dons, Joachim Hinrichs, et al. Spectrochimica Acta Part B, 2011, 66: 144.

    Tools

    Get Citation

    Copy Citation Text

    YANG Guo-wu, HOU Yan-xia, SUN Xiao-fei, JIA Yun-hai, LI Xiao-jia. Evaluation of Long-Term Stability for Non-Standard Method and Application in Trace Element Analysis of Pure Nickel by Glow Discharge Mass Spectrometry[J]. Spectroscopy and Spectral Analysis, 2023, 43(3): 867

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jan. 16, 2022

    Accepted: --

    Published Online: Apr. 7, 2023

    The Author Email: Guo-wu YANG (yangguowu@ncschina.com)

    DOI:10.3964/j.issn.1000-0593(2023)03-0867-10