    Flow chart of life prediction model
    Life test platform of VFD
    Average luminance attenuation data and corresponding Weibull fitting curves
    Fitting curve of accelerated life and accelerated stress by Power function
    • Table 1. Data of the average luminance of VFD attenuating with time under each stress

      View table

      Table 1. Data of the average luminance of VFD attenuating with time under each stress

      jT1=1023.00 KT2=1055.56 KT3=1087.85 KT4=1123.33 K
      tj /hD1(tj) /(cd·m-2)tj /hD2(tj) /(cd·m-2)tj /hD3(tj) /(cd·m-2)tj /hD4(tj) /(cd·m-2)
      001515.8301468.1201490.7301492.65
      1238879.09461051.2246805.8522749.11
      2332734.5192809.9192576.0944516.09
      3426653.41138678.92138432.3566358.80
      4520572.09184596.36206297.2888249.65
      5614526.12230523.61228261.15110160.32
      6708485.70276465.20250223.8613298.80
      7802440.95322411.23272199.22
      8896406.15368364.06294178.36
      9990377.76414331.06316155.80
      101084348.58460298.62338132.40
      111178322.23482280.70
      121272305.19504268.54
      131366273.80526264.92
      141454265.02548249.29
      151542242.49570232.89
      161630225.99592225.45
      171718211.16614215.44
      181806191.06636207.28
      191894178.44658195.48
      201982165.91680189.73
      212048153.11702180.36
      22724170.17
      23746163.27
      24768154.13
    • Table 2. Parameters in the formula of luminance attenuation under each stress

      View table

      Table 2. Parameters in the formula of luminance attenuation under each stress

      ParameterT1=1023.00 KT2=1055.56 KT3=1087.85 KT4=1123.33 K
      Di0 /(cd·m-2)1515.831468.121490.731492.65
      mi0.63020.64770.68140.7555
      ηi577.2547222.338897.700838.5721
      Ri20.99700.99760.99740.9893
    • Table 3. Parameters of goodness-of-fit test based on extrapolated functions

      View table

      Table 3. Parameters of goodness-of-fit test based on extrapolated functions

      Re2RP2βeβP
      0.99950.999729.161121.8637
    • Table 4. Life comparison

      View table

      Table 4. Life comparison

      Itemμ0μeμ1
      Lifetime /h41686.547092.242457.1
      Relative error /%1.8110.92-
    Tools

    Get Citation

    Copy Citation Text

    Jianping Zhang, Yu Zong, Wenqing Zhu, Meng Yi. A Novel Model of Life Prediction for Photoelectric Products and Its Application[J]. Acta Optica Sinica, 2018, 38(2): 0223001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: Aug. 28, 2017

    Accepted: --

    Published Online: Aug. 30, 2018

    The Author Email: Zhang Jianping (jpzhanglzu@163.com)

    DOI:10.3788/AOS201838.0223001

    Topics