Chinese Journal of Lasers, Volume. 37, Issue 5, 1157(2010)
Review and Expectation of Non-Coaxial Laser Confocal Microscopy
[1] [1] M. A. A. Neil,R. Jǔskaitis,T. Wilson et al.. Optimized pupil-plane filters for confocal microscope point-spread function engineering[J]. Opt. Lett.,2000,25(4):245-247
[2] [2] D. M. de Juana,José E. Oti,V. F. Canales et al.. Transverse or axial superresolution in a 4Pi confocal microscope by phase-only filters[J]. J. Opt. Soc. Am. A,2003,20(11):2172-2178
[3] [3] Zhao Weiqian,Tan Jiubin,Qiu Lirong. Bipolar absolute differential confocal approach to higher spatial resolution[J]. Opt. Express,2004,12(21):5013-5021
[4] [4] Zhao Weiqian,Tan Jiubin,Qiu Lirong. Tri-heterodyne confocal microscope with axial superresolution and higher SNR[J]. Opt. Express,2004,12(21):5191-5197
[5] [5] Zhao Weiqian,Qiu Lirong,Feng Zhengde. Effect of fabrication errors on superresolution property of a pupil filter[J]. Opt. Express,2006,14(16):7024-7036
[6] [6] Zhao Weiqian,Qiu Lirong,Chen Shanshan. Image restoration phase-filtering lateral superresolution confocal microscopy[J]. Chin. Phys. Lett.,2006,23(4):856-859
[7] [7] Qiu Lirong,Zhao Weiqian,Feng Zhengde. An approach to higher spatial resolutions in a laser probe measurement system using a phase-only pupil filter[J]. Opt. Eng.,2006,45(11):113601
[10] [10] E. H. K. Stelzer,S. Lindek. Fundamental reduction of the observation volume in far-field light microscopy by detection orthogonal to the illumination axis:confocal theta microscopy[J]. Opt. Commun.,1994,111:536-547
[11] [11] R. H. Webb,F. Rogomentich. Confocal microscope with large field and working distance[J]. Appl. Opt.,1999,38(22):4870-4875
[12] [12] S. Lindek,E. H. K. Steizer. Confocal theta microscopy and 4Pi-confocal theta microscopy[C]. SPIE,1994,2184:188-194
[13] [13] S. Linde,R. Pick,E. H. K. Stelzer. Confocal theta microscope with three objective lenses[J]. Rev. Sci. Instrum,1994,65(11):3367-3372
[14] [14] O. Haeberlé,C. Xu,A. Dieterlen et al.. Multiple-objective microscopy with three-dimensional resolution near 100 nm and a long working distance[J]. Opt. Lett.,2001,26(21):1684-1686
[15] [15] J. Swoger,S. Lindek,T. Stefany et al.. A confocal fiber-coupled single-lens theta microscope (FC-SLTM)[J]. Rev. Sci. Instr.,1998,69(8):2956-2963
[16] [16] M. Rajadhyaksha,P. J. Dwyer,C. A. DiMarzio et al.. Confocal theta line-scanner for imaging skin:a comparison to the point scanner[C]. OSA/FIO 2004,FWM1
[17] [17] P. J. Dwyer,C. A. DiMarzio,J. M. Zavislan et al.. Confocal reflectance theta line scanning microscope for imaging human skin in vivo[J]. Opt. Lett.,2006,31(7):942-944
[18] [18] P. J. Dwyer,C. A. DiMarzio,M. Rajadhyaksha. Confocal theta line-scanning microscope for imaging human tissues[J]. Appl. Opt.,2007,46(10):1843-1851
[19] [19] T. D. Wang,M. J. Mandella,C. H. Contag et al.. Dual-axis confocal microscope for high-resolution in vivo imaging[J]. Opt. Lett.,2003,28(6):414-416
[20] [20] T. D. Wang,C. H. Contag,M. J. Mandella et al.. Dual-axes confocal microscopy with post-objective scanning and low-coherence heterodyne detection[J]. Opt. Lett.,2003,28(20):1915-1917
[21] [21] T. D. Wang,C. H. Contag,M. J. Mandella et al.. Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning[J]. J. Biomed. Opt.,2004,9(4):735-742
[22] [22] G. Kino,T. Wang,C. Contag et al.. Performance of dual axes confocal microscope for in vivo molecular and cellular imaging[C]. SPIE,2004,5324:35-46
[23] [23] J. T. C. Liu,M. J. Mandella,S. Friedland et al.. Dual-axes confocal reflectance microscope for distinguishing colonic neoplasia[J]. J. Biomed. Opt.,2006,11(5):054019
[24] [24] Hyejun Ra,I. Jung,D. Lee et al.. High-resolution microelectromechanical scanners for miniaturized dual-axes confocal microscopes[C]. SPIE,2005,5721:132-135
[25] [25] J. T. C. Liu,M. J. Mandella,H. Ra et al.. Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner[J]. Opt. Lett.,2007,32(3):256-258
[26] [26] H. Ra,W. Piyawattanametha,Y. Taguchi et al.. Two-dimensional MEMS scanner for dual-axes confocal microscopy[J]. J. Microelectromenchanical Systems,2007,16(4):969-976
[27] [27] H. Ra,W. Piyawattanametha,Y. Taguchi et al.. Reflectance and fluorescence imaging with a MEMS dual-axes confocal microscope[C]. SPIE,2007,6466:64660G
[28] [28] M. J. Mandella,J. T. C. Liu,W. Piyawattanametha et al.. Compact optical design for dual-axes confocal endoscopic microscopes[C]. SPIE,2007,6443:64430E
[29] [29] H. Ra,W. Piyawattanametha,M. J. Mandella et al.. Three-dimensional in vivo imaging by a handheld dual-axes confocal microscope[J]. Opt. Express,2008,16(10):7224-7232
[30] [30] K. Loewke,D. Camarilloa,W. Piyawattanamethab et al.. Real-time image mosaicing with a hand-held dual-axes confocal microscope[C]. SPIE,2008,6851:68510F
[31] [31] W. Piyawattanametha,H. Ra,M. J. Mandella et al.. In vivo clinical and intravital imaging with MEMS based dual-axes confocal microscopes[C]. in NTM 2009,NWC1
[32] [32] Zhao Weiqian,Tan Jiubin,Qiu Lirong et al.. A new laser heterodyne confocal probe for ultraprecision measurement of discontinuous contours[J]. Measure. Sci. Technol.,2005,16(2):497-504
[33] [33] Zhao Weiqian,Tan Jiubin,Qiu Lirong. Improvement of confocal microscope performance by shaped annular beam and heterodyne confocal techniques[J]. Optik,2005,116(3):111-117
Get Citation
Copy Citation Text
Sha Dingguo, Jiang Qin, Zhao Weiqian, Qiu Lirong. Review and Expectation of Non-Coaxial Laser Confocal Microscopy[J]. Chinese Journal of Lasers, 2010, 37(5): 1157
Category: reviews
Received: Mar. 31, 2009
Accepted: --
Published Online: May. 11, 2010
The Author Email: Sha Dingguo (shadingguo@263.net)