Journal of Radiation Research and Radiation Processing, Volume. 41, Issue 6, 060301(2023)

Effects of automatic registration range settings of cone-beam computed tomography (CBCT) on target volume accuracy and clinical applications for breast cancer

Guoquan CHEN, Jiannan FANG, Jin YANG, Huan LI, Xixian WANG, Zairen GUO, Yujia MA, Juntian SHI, and Xiaobo HUANG*
Figures & Tables(5)
Illustration of registration range of different matching frames for CBCT of breast cancer patients and position fixation device (a, b, c are sternum group, thoracic group, and research group)
3D vector distance frequency distribution of metal clips in the target area of three matching frames in 22 breast cancer IMRT patients
3D vector distance histogram of metal clips in the target area of three matching frames in 22 breast cancer IMRT patients
  • Table 1. Comparison of IMRT linear placement and rotation errors in three different matching box of 22 patients with breast cancer

    View table
    View in Article

    Table 1. Comparison of IMRT linear placement and rotation errors in three different matching box of 22 patients with breast cancer

    项目

    Project

    胸骨组

    Sternum group

    胸椎组

    Thoracic group

    胸骨胸椎+靶区组

    Research group

    p*

    p value*

    平移误差 Linear error / mm
    XX-axis (Left-right)2.57±1.802.49±1.902.31±1.790.434a、0.999b、0.990c
    YY-axis (The head and foot)2.91±2.052.79±2.312.75±2.130.999a、0.987b、0.792c
    ZZ-axis (The abdomen and back)2.58±2.082.63±2.292.34±1.880.869a、0.999b、0.999c
    旋转误差 Rotation error / (°)
    RxRx (Pitch)0.86±0.640.76±0.600.69±0.550.034a、0.812b、0.460c
    RyRy (Roll)0.85±0.620.77±0.600.80±0.560.999a、0.976b、0.658c
    RzRz (Yaw)0.72±0.580.75±0.640.66±0.550.971a、0.505b、0.999c
  • Table 2. Comparison of IMRT CBCT imaging and CT imaging target positioning metal clip displacement in three different matching box of 22 patients with breast cancer

    View table
    View in Article

    Table 2. Comparison of IMRT CBCT imaging and CT imaging target positioning metal clip displacement in three different matching box of 22 patients with breast cancer

    项目

    Project

    胸骨组

    Sternum group

    胸椎组

    Thoracic group

    胸骨胸椎+靶区组

    Research group

    p*

    pvalue*

    XX-axis (Left-right)1.59±1.611.65±1.441.13±1.180.045a、0.002b、0.952c
    YY-axis (The head and foot)1.51±1.831.69±1.840.91±1.280.006a、<0.001b、0.817c
    ZZ-axis (The abdomen and back)1.23±1.191.89±1.521.37±1.310.999a、0.003b、<0.001c
Tools

Get Citation

Copy Citation Text

Guoquan CHEN, Jiannan FANG, Jin YANG, Huan LI, Xixian WANG, Zairen GUO, Yujia MA, Juntian SHI, Xiaobo HUANG. Effects of automatic registration range settings of cone-beam computed tomography (CBCT) on target volume accuracy and clinical applications for breast cancer[J]. Journal of Radiation Research and Radiation Processing, 2023, 41(6): 060301

Download Citation

EndNote(RIS)BibTexPlain Text
Save article for my favorites
Paper Information

Category: Research Articles

Received: May. 16, 2023

Accepted: Jul. 2, 2023

Published Online: Jan. 3, 2024

The Author Email: Xiaobo HUANG (黄晓波)

DOI:10.11889/j.1000-3436.2023-0035

Topics