Chinese Journal of Lasers, Volume. 47, Issue 1, 0111002(2020)
Carbon Monoxide Detection Based on Photoacoustic Spectroscopy
[1] Prockop L D, Chichkova R I. Carbon monoxide intoxication: an updated review[J]. Journal of the Neurological Sciences, 262, 122-130(2007).
[2] Logan J A, Prather M J, Wofsy S C et al. Tropospheric chemistry: a global perspective[J]. Journal of Geophysical Research, 86, 7210-7254(1981).
[4] Smith R N, Swinehart J, Lesnini D G. Chromatographic analysis of gas mixtures containing nitrogen, nitrous oxide, nitric oxide, carbon monoxide, and carbon dioxide[J]. Analytical Chemistry, 30, 1217-1218(1958).
[5] Ary S, Dockter K, Nielsen A et al. United states environmental protection agency[J]. Proceedings of the Water Environment Federation, 2005, 726-737(2005).
[6] Yang J C, Zhou J X, Lü Z et al. A real-time monitoring system of industry carbon monoxide based on wireless sensor networks[J]. Sensors, 15, 29535-29546(2015).
[7] Hodgkinson J, Smith R, Ho W O et al. Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor[J]. Sensors and Actuators B: Chemical, 186, 580-588(2013).
[8] Peng X J. Study on photoacoustic spectroscopy detection and response characteristic of carbon monoxide[D]. Chongqing: Chongqing University, 1-18(2013).
[9] Schramm D U. Sthel M S, da Silva M G, et al. Application of laser photoacoustic spectroscopy for the analysis of gas samples emitted by diesel engines[J]. Infrared Physics & Technology, 44, 263-269(2003).
[10] Sigrist M W, Winefordner J D, Kolthoff I M. Air monitoring by spectroscopic techniques[M]. New York: John Wiley & Sons, Inc., 25-28(1994).
[11] He Y, Ma Y F, Tong Y et al. Ultra-high sensitive light-induced thermoelastic spectroscopy sensor with a high Q-factor quartz tuning fork and a multipass cell[J]. Optics Letters, 44, 1904-1907(2019).
[15] Edwards H O, Dakin J P. Gas sensors using correlation spectroscopy compatible with fibre-optic operation[J]. Sensors and Actuators B: Chemical, 11, 9-19(1993).
[16] Qiao S D, Ma Y F, He Y et al. A sensitive carbon monoxide sensor based on photoacoustic spectroscopy with a 2.3 μm mid-infrared high-power laser and enhanced gas absorption[J]. Sensors, 19, 3202(2019).
[18] Narasimhan L R, Goodman W. Patel C K N. Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis[J]. Proceedings of the National Academy of Sciences, 98, 4617-4621(2001).
[19] Kerr E L, Atwood J G. The laser illuminated absorptivity spectrophone: a method for measurement of weak absorptivity in gases at laser wavelengths[J]. Applied Optics, 7, 915-921(1968).
[21] Wu H P, Dong L, Zheng H D et al. Enhanced near-infrared QEPAS sensor for sub-ppm level H2S detection by means of a fiber amplified 1582 nm DFB laser[J]. Sensors and Actuators B: Chemical, 221, 666-672(2015).
[22] Slowik J G, Cross E S, Han J H et al. An inter-comparison of instruments measuring black carbon content of soot particles[J]. Aerosol Science and Technology, 41, 295-314(2007).
[23] Bakhirkin Y A, Kosterev A A, Curl R F et al. Sub-ppbv nitric oxide concentration measurements using CW thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy[J]. Applied Physics B, 82, 149-154(2006).
[24] Ma Y F, Lewicki R, Razeghi M et al. QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL[J]. Optics Express, 21, 1008-1019(2013).
[25] Ma Y F, Tong Y, He Y et al. Compact and sensitive mid-infrared all-fiber quartz-enhanced photoacoustic spectroscopy sensor for carbon monoxide detection[J]. Optics Express, 27, 9302-9312(2019).
[26] Wei T T, Wu H P, Yin X K et al. Impact of humidity and SF6 on CO detection based on quartz-enhanced photoacoustic spectroscopy[J]. Optics and Precision Engineering, 26, 1870-1875(2018).
[30] Zhou Y, Cao Y, Zhu G D et al. Detection of nitrous oxide by resonant photoacoustic spectroscopy based on mid infrared quantum cascade laser[J]. Acta Physica Sinica, 67, 084201(2018).
[33] Wysocki G, Kosterev A A, Tittel F K. Influence of molecular relaxation dynamics on quartz-enhanced photoacoustic detection of CO2 at λ=2 μm[J]. Applied Physics B, 85, 301-306(2006).
[34] Schilt S, Besson J P, Thévenaz L. Near-infrared laser photoacoustic detection of methane: the impact of molecular relaxation[J]. Applied Physics B, 82, 319-328(2006).
[35] Kalkman J, van Kesteren H W. Relaxation effects and high sensitivity photoacoustic detection of NO2 with a blue laser diode[J]. Applied Physics B, 90, 197-200(2008).
Get Citation
Copy Citation Text
Xin Liu, Ting Zhang, Gang Zhang, Guangzhen Gao, Tingdong Cai. Carbon Monoxide Detection Based on Photoacoustic Spectroscopy[J]. Chinese Journal of Lasers, 2020, 47(1): 0111002
Category: spectroscopy
Received: Jul. 22, 2019
Accepted: Sep. 26, 2019
Published Online: Jan. 9, 2020
The Author Email: Tingdong Cai (caitingdong@126.com)