Acta Optica Sinica, Volume. 40, Issue 1, 0111017(2020)
Optimization of Detection Angle for Pinhole X-Ray Fluorescence Computed Tomography
[1] Deng L Z, Wei B, He P et al. A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging[J]. International Journal of Nanomedicine, 13, 7207-7216(2018).
[3] Jones B L, Krishnan S, Cho S H. Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations[J]. Medical Physics, 37, 3809-3816(2010).
[6] Fu G, Meng L J, Eng P et al. Experimental demonstration of novel imaging geometries for X-ray fluorescence computed tomography[J]. Medical Physics, 40, 061903(2013).
[7] Liu L, Huang Y, Xu Q et al. Attenuation correction of L-shell X-ray fluorescence computed tomography imaging[J]. Chinese Physics C, 39, 038203(2015).
[10] Li L, Zhang S Y, Li R Z et al. Full-field fan-beam X-ray fluorescence computed tomography with a conventional X-ray tube and photon-counting detectors for fast nanoparticle bioimaging[J]. Optical Engineering, 56, 043106(2017).
[11] Jung S, Kim T, Lee W et al. Dynamic in vivo X-ray fluorescence imaging of gold in living mice exposed to gold nanoparticles[J]. IEEE Transactions on Medical Imaging, 1(2019).
[12] Takeda T, Akiba M, Yuasa T et al. Fluorescent X-ray computed tomography with synchrotron radiation using fan collimator[J]. Proceedings of SPIE, 2708, 685-695(1996).
[13] Zhang S, Li L, Chen J et al. Quantitative imaging of Gd nanoparticles in mice using benchtop cone-beam X-ray fluorescence computed tomography system[J]. International Journal of Molecular Sciences, 20, 2315(2019).
[14] Ahmad M, Bazalova-Carter M, Fahrig R et al. Optimized detector angular configuration increases the sensitivity of X-ray fluorescence computed tomography (XFCT)[J]. IEEE Transactions on Medical Imaging, 34, 1140-1147(2015).
[15] Kuang Y, Pratx G, Bazalova M et al. Development of XFCT imaging strategy for monitoring the spatial distribution of platinum-based chemodrugs: instrumentation and phantom validation[J]. Medical Physics, 40, 030701(2013).
[18] Dunning S, Bazalova-Carter M. Optimization of a table-top X-ray fluorescence computed tomography (XFCT) system[J]. Physics in Medicine & Biology, 63, 235013(2018).
[19] Poludniowski G, Landry G. DeBlois F, et al. SpekCalc: a program to calculate photon spectra from tungsten anode X-ray tubes[J]. Physics in Medicine and Biology, 54, N433-N438(2009).
[21] Lange K, Carson R. EM reconstruction algorithms for emission and transmission tomography[J]. Journal of Computer Assisted Tomography, 8, 306-316(1984).
[22] Dickerscheid D, Lavalaye J, Romijn L et al. Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols[J]. EJNMMI Research, 3, 21(2013).
Get Citation
Copy Citation Text
Jing Guo, Peng Feng, Luzhen Deng, Yan Luo, Peng He, Biao Wei. Optimization of Detection Angle for Pinhole X-Ray Fluorescence Computed Tomography[J]. Acta Optica Sinica, 2020, 40(1): 0111017
Category: Special Issue on Computational Optical Imaging
Received: Jul. 23, 2019
Accepted: Oct. 8, 2019
Published Online: Jan. 6, 2020
The Author Email: Feng Peng (coe-fp@cqu.edu.cn), He Peng (penghe@cqu.edu.cn)