Chinese Journal of Lasers, Volume. 47, Issue 8, 811001(2020)

Adaptive Selection Method for Analytical Lines in Laser-Induced Breakdown Spectra

Pan Lijian, Chen Weifang*, Cui Rongfang, and Li Miaomiao
Author Affiliations
  • College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics,Nanjing, Jiangsu 210001, China
  • show less
    Figures & Tables(10)
    Flowchart of PSO-GA algorithm
    Schematic diagram of LIBS experimental system
    Spectrum of aluminum alloy
    Calibration curves based on optimal spectral lines. (a) Mg; (b) Mn; (c) Si; (d) Fe
    Comparison of fitness values between the optimal line and other spectral lines. (a) Mn; (b) Si
    Comparison of goodness of fit between the optimal line and other spectral lines. (a) Mn; (b) Si
    Evolutionary graphs of different methods
    • Table 1. Content of main non-Al elements in different standard samples of aluminum alloy%

      View table

      Table 1. Content of main non-Al elements in different standard samples of aluminum alloy%

      Standard sampleSiFeMnMg
      30030.1350.3841.0700.013
      50520.1200.1500.0062.56
      50830.0440.0860.6174.22
      59620.5870.3920.4173.41
      60610.6400.5460.0941.00
      6063a0.3900.1350.00360.825
      6063b0.4190.1870.0550.540
    • Table 2. Results of optimal characteristic lines optimized by PSO-GA

      View table

      Table 2. Results of optimal characteristic lines optimized by PSO-GA

      Analytical elementGeneration numberAnalytical lines /nmReference lines /nmFGR2
      Mg38277.986236.8700.5030.991
      Mn31259.365265.2490.6360.987
      Si25288.158396.1711.0290.936
      Fe43274.627396.1710.7450.972
    • Table 3. Comparison of optimization results calculated by different methods

      View table

      Table 3. Comparison of optimization results calculated by different methods

      MethodGenerationnumberConvergencetime /sFG
      PSO3618.70.721
      GA5431.50.636
      PSO-GA3121.40.636
    Tools

    Get Citation

    Copy Citation Text

    Pan Lijian, Chen Weifang, Cui Rongfang, Li Miaomiao. Adaptive Selection Method for Analytical Lines in Laser-Induced Breakdown Spectra[J]. Chinese Journal of Lasers, 2020, 47(8): 811001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: spectroscopy

    Received: Mar. 10, 2020

    Accepted: --

    Published Online: Aug. 17, 2020

    The Author Email: Weifang Chen (meewfchen@nuaa.edu.cn)

    DOI:10.3788/CJL202047.0811001