Chinese Journal of Ship Research, Volume. 16, Issue 4, 199(2021)

Fault tolerant communication technology of configuration monitoring system based on integration of DMA and interrupt

Wanfeng SUN1, Weibo LI1,2, Qi LI1, Zhenjie ZHOU1, and Yue LU1
Author Affiliations
  • 1School of Automation, Wuhan University of Technology, Wuhan 430070, China
  • 2Institute of Oxgen Supply, Tibet University, Lhasa 850012, China
  • show less
    Figures & Tables(14)
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    • Table 1. Interrupt priority of DMA controller timing

      View table
      View in Article

      Table 1. Interrupt priority of DMA controller timing

      中断类别抢占优先级响应优先级
      串口接收中断22
      串口发送DMA中断22
    • Table 2. Results of two communication methods

      View table
      View in Article

      Table 2. Results of two communication methods

      通信方式接收次数丢包率/%
      DMA与中断方式串口通信4 7505
      传统定长收发串口通信3 00040
    Tools

    Get Citation

    Copy Citation Text

    Wanfeng SUN, Weibo LI, Qi LI, Zhenjie ZHOU, Yue LU. Fault tolerant communication technology of configuration monitoring system based on integration of DMA and interrupt[J]. Chinese Journal of Ship Research, 2021, 16(4): 199

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Marine Machinery, Electrical Equipment and Automation

    Received: Apr. 27, 2020

    Accepted: --

    Published Online: Mar. 28, 2025

    The Author Email:

    DOI:10.19693/j.issn.1673-3185.01935