    Figures & Tables(13)
    Response model for a cooled infrared pixel
    Schematic diagram of experimental setup
    Experiment scenario
    The relationship between radiation brightness and system grayscale at different integration times
    The relationship between integration time and system grayscale at different blackbody temperatures
    Three-dimensional distribution of calibration parameters
    Schematic diagram of bad pixels compensation effect
    Efficiency analysis of rapid wide dynamic non-uniformity algorithm
    Comparison of corrected residuals of the original image, conventional NUC, and the algorithms mentioned in this paper at different integration times
    Comparison of correction effects by different algorithms with the same integration time (0.6 ms). (a) Raw image; (b) the traditional NUC algorithm results; (c) the proposed NUC algorithm results
    Comparison of calibration effects by different algorithms with different integration times. (a) t=3 ms; (b) t=3.1 ms; (c) t=3.5 ms. (i) Raw image; (ii) traditional NUC algorithm results; (iii) the proposed NUC algorithm results
    • Table 1. Basic parameters of the proposed infrared system

      View table
      View in Article

      Table 1. Basic parameters of the proposed infrared system

      ParameterValue
      Response band/μm3.7~4.8
      Pixel numbers320×256
      Pixel size/μm30
      NETD/mK15
      Number resolution (bit)14
      Cooled temperature/K77
      Focal length/mm50
      F/#2
    • Table 2. Average value of radiometric calibration parameters

      View table
      View in Article

      Table 2. Average value of radiometric calibration parameters

      ParametersValue
      $ \overline {{R_n}} $573
      $ \overline {{d_t}} $192
      $ \overline {{d_{{{in}}}}} $1251
    Tools

    Get Citation

    Copy Citation Text

    Zhou LI, Yao-yu ZHANG, Hui ZHOU, Xiang-long KONG, Xin-yu ZHAO, Xiang-chen LI. Rapid wide dynamic non-uniformity correction algorithm for infrared radiation measurement system[J]. Chinese Optics, 2024, 17(6): 1359

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 4, 2023

    Accepted: --

    Published Online: Jan. 14, 2025

    The Author Email:

    DOI:10.37188/CO.2023-0076