Infrared and Laser Engineering, Volume. 51, Issue 9, 20210933(2022)

Calibration method and accuracy evaluation of visual target with double screen for straight pipe jacking machine

Zhe Huang1, Qingde Yan1, Qian Li2、*, Erjing Cheng1, Xiaoling Shen1, and Yeqian Xu1
Author Affiliations
  • 1School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin 300222, China
  • 2Tianjin Samsung Vision Mobile Co., Ltd., Tianjin 300385, China
  • show less
    Figures & Tables(12)
    Measurement model of visual target with double screen
    Definition diagram of coordinate frames
    Schematic diagram of grid calibration
    Schematic diagram of three common point coordinate frame conversion algorithm
    Schematic diagram of grid index
    Experimental environment for grid calibration
    (a) Repeatability accuracy of static measurement of coordinates; (b) Repeatability accuracy of static measurement of heading angle
    Schematic diagram of heading angle measurement accuracy evaluation experiment
    Experimental data of heading angle measurement accuracy evaluation
    • Table 1. Parameters of hardware

      View table
      View in Article

      Table 1. Parameters of hardware

      NameParameter
      CameraModel:Basler aca1300-60 gm
      Resolution:1280×1024 pixel
      Pixel size:5.3 μm×5.3 μm
      Frame rate:60 fps
      Total stationModel:Leica TS12
      Ranging accuracy:2 mm±2 ppm
      Angle accuracy:2″
      Repeatability precision:0.1 mm
      InclinometerAngle accuracy:0.01°
      One dimensional turntableAngle accuracy:2″
    • Table 2. Experiment data of coordinate accuracy evaluation

      View table
      View in Article

      Table 2. Experiment data of coordinate accuracy evaluation

      No.X/mm Y/mm Z/mm ${d_{{X} } }$/mm ${d_{{Y} } }$/mm ${d_{{Z} } }$/mm
      1$P_{\text{0} }^{{s} }$24.48−25.3179.78−0.330.26−0.12
      $P_{\text{1} }^{{s} }$24.15−25.0579.66
      2$P_{\text{0} }^{{s} }$69.87−25.3050.30−0.94−0.63−0.73
      $P_{\text{1} }^{{s} }$68.93−25.9349.57
      3$P_{\text{0} }^{{s} }$11.12−25.6931.06−0.43−0.770.51
      $P_{\text{1} }^{{s} }$10.69−26.4631.57
      4$P_{\text{0} }^{{s} }$−60.41−25.768.43−0.240.18−0.14
      $P_{\text{1} }^{{s} }$−60.65−25.588.29
      5$P_{\text{0} }^{{s} }$53.42−26.47−66.79−0.83−0.72−0.34
      $P_{\text{1} }^{{s} }$52.59−27.19−67.13
      6$P_{\text{0} }^{{s} }$64.26−25.73−43.86−0.27−0.17−0.18
      $P_{\text{1} }^{{s} }$63.99−25.9−44.04
    • Table 3. Errors analysis

      View table
      View in Article

      Table 3. Errors analysis

      Error typeError source
      Calibration errors of dual screen visual targetThe error of image recognition
      The error of total station measurement
      The error of coordinate system conversion
      Measurement errors of attitude anglesCalculating error of light vector
      The error of inclinometer measurement
    Tools

    Get Citation

    Copy Citation Text

    Zhe Huang, Qingde Yan, Qian Li, Erjing Cheng, Xiaoling Shen, Yeqian Xu. Calibration method and accuracy evaluation of visual target with double screen for straight pipe jacking machine[J]. Infrared and Laser Engineering, 2022, 51(9): 20210933

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Photoelectric measurement

    Received: Mar. 20, 2022

    Accepted: --

    Published Online: Jan. 6, 2023

    The Author Email: Li Qian (qian02.li@samsung.com)

    DOI:10.3788/IRLA20210933

    Topics