Journal of Infrared and Millimeter Waves, Volume. 42, Issue 3, 369(2023)

Research on nonlinear correction algorithm of Fourier transform spectrometer based on responsivity correction

Yao-Pu ZOU1,2, Xuan FENG3、*, Chang-Pei HAN1,2、**, Li-Bing LI1,2, Xiao LIANG2,4, Jing QIAN1,2, and Xiu-Ju LI1,2
Author Affiliations
  • 1Key Laboratory of Infrared System Detection and Imaging Technology, Shanghai 200083, China
  • 2Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
  • 3Key Laboratory of Space Utilization, Technology and Engineering center for Space Utilization, Chinese Academy of Sciences, Beijing 100094, China
  • 4University of Chinese Academy of Sciences, Beijing 100049, China
  • show less

    Fourier transform spectrometer shows great advantages in the field of quantitative remote sensing. Nonlinear correction is an important part to ensure the accuracy of on-orbit radiometric calibration. The FY-4/GIIRS located in the stationary orbit has the characteristics of uneven sunlight exposure and severe daily changes in the background temperature of the instrument. A nonlinear correction algorithm based on instrument spectral responsivity correction is derived. By measuring a set of standard reference radiation source spectral quantification values and spectral responsivity, fitting the correction coefficient of the primary term of spectral responsivity. After the ambient temperature of the instrument changes, the correction coefficient of the response rate constant term can be recalculated using the correction coefficient of the first-order term, the spectral value and the spectral responsivity of the black body observation, and the nonlinear correction coefficient of the instrument under any instrument background temperature can be obtained. Verified by the ground thermal vacuum (TVAC) calibration tests data before the launch of the instrument, the algorithm is simple and effective. In each ambient temperature test, the radiometric calibration accuracy in the observation range of 180-320 K has been improved significantly.

    Tools

    Get Citation

    Copy Citation Text

    Yao-Pu ZOU, Xuan FENG, Chang-Pei HAN, Li-Bing LI, Xiao LIANG, Jing QIAN, Xiu-Ju LI. Research on nonlinear correction algorithm of Fourier transform spectrometer based on responsivity correction[J]. Journal of Infrared and Millimeter Waves, 2023, 42(3): 369

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Oct. 26, 2022

    Accepted: --

    Published Online: Jul. 5, 2023

    The Author Email: Xuan FENG (fengxuan@csu.ac.cn), Chang-Pei HAN (changpei_han@mail.sitp.ac.cn)

    DOI:10.11972/j.issn.1001-9014.2023.03.012

    Topics