Photonics Research, Volume. 10, Issue 11, 2614(2022)
Mid-infrared single-photon upconversion spectroscopy based on temporal-spectral quantum correlation Editors' Pick
Fig. 1. Schematic flow diagram of the MIR upconversion quantum spectroscopy based on temporal-spectral correlation. Inset, normalized JSI of the SPDC process pumped by a 1032.88 nm laser with a linewidth of about 2.78 nm in a 25-mm-long MgO-doped CPLN with the poling period from 23.0 μm to 32.0 μm.
Fig. 2. Schematic of the MIR upconversion quantum spectroscopy experimental setup, including the broadband SPDC photon-pair source, the MIR frequency upconversion module (UPC), and the correlation-based spectrum detection module.
Fig. 3. Spectra of NIR heralding photons via a monochromator together with the SNSPD (cyan circles) and upconverted signal photons via a spectrograph with an exposure time of 90 s (purple line) when pump power for SPDC is 5 mW.
Fig. 4. Coincidence counting rate (black squares) and CAR value (red circles) as a function of pump power for SPDC. Solid curves represent a fit to the experimental data. Inset, typical coincidence histogram at the pump power for
Fig. 5. Coincidence spectrum by scanning the wavelength of the heralding photon. The shaded error band represents the standard deviation obtained from several independent measurements with an acquisition time of 90 s for each. Inset, time correlation histogram of photon pairs at the heralding photon wavelength of 1503.45 nm.
Fig. 6. Transmission spectra of PS film with thickness of 38 μm. Dots represent the spectrum measured via the MIR upconversion spectroscopy system based on temporal-spectral quantum correlation. Solid line represents the spectrum measured via a commercial FTIR spectrometer as a comparison. The shaded error bands represent the accuracy of the transmittance spectrum obtained by the coincidence detection.
Fig. 7. Measured photon number of heralding photons
Fig. 8. Transmission spectra of plastic samples, including (a) 50 μm PS film, (b) PE cling film, and (c) 18.6 μm PMMA film that are measured by using the commercial FTIR spectrometer (lines) or MIR upconversion spectroscopy system based on the temporal-spectral quantum correlation (scatters). The shaded error bands represent the accuracy of the transmission spectrum obtained by the coincidence detection.