Chinese Journal of Liquid Crystals and Displays, Volume. 38, Issue 9, 1205(2023)

Visual fatigue measurement of display mode based on ECG and eye movement signal

Li-xiu JIA1,2、*, Sheng HUANG1, Yi-quan DING1, Yan TU2, and Li-li WANG2
Author Affiliations
  • 1School of Computer Engineering,Nanjing Institute of Technology,Nanjing 211167,China
  • 2School of Electronic Science and Engineering,Southeast University,Nanjing 210096,China
  • show less
    Figures & Tables(12)
    Schematic of experiment procedure
    Schematic diagram of experiment
    Mean values of ophthalmological parameters before and after watching 2D and 3D display modes.(a)BCDVA;(b)BCNVA;(c)CSF;(d)TBUT. Error bars indicate standard deviation(**:p<0.01).
    Mean values and standard deviation of(a)R_ BCDVA and(b)R_TBUT under 2D and 3D display modes(**:p<0.01).
    Mean values of MMPD before and after watching 2D and 3D display. Error bars indicate standard deviation(**:p<0.01).
    Mean values and standard deviation of R_MMPD under 2D and 3D display modes(**:p<0.01).
    Mean values of ECG parameters before and after watching 2D and 3D display modes during E-book reading.(a)LF Power(ms2);(b)HF Power(%);(c)Shannon Entropy. Error bars indicate standard deviation(**:p<0.01).
    Mean values and standard deviation for R_Shannon Entropy under 2D and 3D display modes(*:p<0.05).
    Mean values of subjective symptoms score before and after watching(a)2D and(b)3D display. Error bars indicate standard deviation(**:p<0.01;*:p<0.05).
    Mean values and standard deviation for relative subjective symptoms score before and after watching 2D and 3D display(*:p<0.05).
    Trend of(a)R_RR,(b)R_HR and(c)R_LF Power(ms2)over time during watching 2D and 3D display. Error bars indicate standard deviation(*:p<0.05).
    • Table 1. ANOVA results of relative ECG parameters during watching 2D and 3D display

      View table
      View in Article

      Table 1. ANOVA results of relative ECG parameters during watching 2D and 3D display

      因变量自变量统计检验量F显著性水平Sig.效应量η2p
      R_RR时间2.310.0060.07
      显示模式11.30<0.0050.03
      R_HR时间2.79<0.0050.09
      显示模式12.59<0.0010.03
      R_LF Power(ms2时间2.56<0.0050.08
      显示模式11.990.0010.03
    Tools

    Get Citation

    Copy Citation Text

    Li-xiu JIA, Sheng HUANG, Yi-quan DING, Yan TU, Li-li WANG. Visual fatigue measurement of display mode based on ECG and eye movement signal[J]. Chinese Journal of Liquid Crystals and Displays, 2023, 38(9): 1205

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Oct. 6, 2022

    Accepted: --

    Published Online: Sep. 19, 2023

    The Author Email: Li-xiu JIA (jialixiu@njit.edu.cn)

    DOI:10.37188/CJLCD.2022-0324

    Topics