Infrared and Laser Engineering, Volume. 54, Issue 8, 20250149(2025)

Data calibration and imaging for division-of-focal-plane polarization-integrated mid-wave infrared detectors

Long WANG1,2, Jian ZHOU2,3, Yaoyun CAO1,2, Fangfang WANG2,3, Xiangxiao YING3, Shouhai TANG3, Lingfang WANG1, Yunmeng LIU2,4, Yi ZHOU1,2,3, and Jianxin CHEN1,2,3
Author Affiliations
  • 1School of Physics and Optoelectronic Engineering, Hangzhou Institute of Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310024, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • 3National Key Laboratory of Infrared Detection Technologies, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
  • 4Key Laboratory of Infrared System Detection and Imaging Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
  • show less
    Figures & Tables(10)
    Polarization super-pixel structure
    Response model of division-of-focal-plane polarization integrated detector
    Ideal normalized response curves of pixels in four polarization directions
    Polarization integrated infrared detector test system
    (a) Superpixel response curves; (b) Response curves of different pixels in the same detection direction; (c) Comparison curves of normal pixels and blind pixels
    (a) Dead blind and thermal blind detected by the national standard method; (b) The response blind and polarization blind detected by the proposed method
    (a) Original intensity image; (b) Intensity image after non-uniformity correction of the national standard method and blind pixel replacement; (c) Intensity image after non-uniformity correction of the proposed method and blind pixel replacement; (d) Polarization image; (e) Polarization angle image
    • Table 1. The non-uniformity of the detector at different blackbody temperatures

      View table
      View in Article

      Table 1. The non-uniformity of the detector at different blackbody temperatures

      Data type15 ℃25 ℃35 ℃
      Raw data2.08002.18002.0900
      Response correction data0.03960.03880.0385
      Polarization correction data0.02330.02370.0226
    • Table 2. The blind element determination parameters of the proposed method

      View table
      View in Article

      Table 2. The blind element determination parameters of the proposed method

      Parameter45°90°135°
      Mean(RSE)0.00690.00710.00630.0062
    • Table 3. Blind metadata statistics table

      View table
      View in Article

      Table 3. Blind metadata statistics table

      Detect methodBlind element category45°90°135°
      National standard methodDead pixel51168
      Overheated pixel129126133124
      Total blind elementTotal: 542, blindness rate: 0.662%
      The proposed methodResponse blind element140142146135
      Polarization blind element8182634
      Repetition number6172330
      Total blind elementTotal: 573, blindness rate: 0.699%
    Tools

    Get Citation

    Copy Citation Text

    Long WANG, Jian ZHOU, Yaoyun CAO, Fangfang WANG, Xiangxiao YING, Shouhai TANG, Lingfang WANG, Yunmeng LIU, Yi ZHOU, Jianxin CHEN. Data calibration and imaging for division-of-focal-plane polarization-integrated mid-wave infrared detectors[J]. Infrared and Laser Engineering, 2025, 54(8): 20250149

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical imaging, display and information processing

    Received: Mar. 4, 2025

    Accepted: --

    Published Online: Aug. 29, 2025

    The Author Email:

    DOI:10.3788/IRLA20250149

    Topics