Chinese Optics Letters, Volume. 6, Issue 12, 905(2008)

In vitro birefringence imaging with spectral domain polarization-sensitive optical coherence tomography

Qiang Gong1,2、*, Chuanmao Fan1,2, Fan Zhang1,2, and Jianquan Yao1,2
Author Affiliations
  • 1Key Laboratory of Optoelectric Information Science and Technology, Ministry of Education, Tianjin University, Tianjin 300072
  • 2Institute of Laser and Optoelectronics, College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072
  • show less
    References(20)

    [1] [1] D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and J. G. Fujimoto, Science 254, 1178 (1991).

    [2] [2] A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, Opt. Commun. 117, 43 (1995).

    [3] [3] P. Bu, X. Wang, and O. Sasaki, Acta Opt. Sin. (in Chinese) 27, 1470 (2007).

    [4] [4] Y. Chen, Z. Ding, and J. Meng, Chinese J. Lasers (in Chinese) 34, 825 (2007).

    [5] [5] G. Hausler and M. W. Lindner, J. Biomed. Opt. 3, 21 (1998).

    [6] [6] H. M. Jones, R. J. Baskin, and Y. Yeh, Biophys. J. 60, 1217 (1991).

    [7] [7] P. Whittaker and P. B. Canham, Matrix 11, 56 (1991).

    [8] [8] A. Boyde, P. Bianco, M. P. Barbos, and A. Ascenzi, Metab. Bone Dis. Relat. Res. 5, 299 (1984).

    [9] [9] Y. E. Yarker, R. M. Aspden, and D. W. L. Hukins, Connect. Tissue Res. 11, 207 (1983).

    [10] [10] R. Ortmann, Anat. Embryol. 148, 109 (1975).

    [11] [11] V. Sankaran and J. T. Walsh, Jr., Photochem. Photobiol. 68, 846 (1998).

    [12] [12] V. J. lafelice and W. S. Bickel, Appl. Opt. 26, 2410 (1987).

    [13] [13] J. F. de Boer, T. E. Milner, M. J. C. van Gemert, and J. S. Nelson, Opt. Lett. 22, 934 (1997).

    [14] [14] J. F. de Boer, S. M. Srinivas, A. Malekafzali, Z. Chen, and J. S. Nelson, Opt. Express 6, 212 (1998).

    [15] [15] M. J. Everett, K. Schoenenberger, B. W. Colston, Jr., and L. B. Da Silva, Opt. Lett. 23, 228 (1998).

    [16] [16] K. Schoenenberger, B. W. Colston, Jr., D. J. Maitland, L. B. Da Silva, and M. J. Everett, Appl. Opt. 37, 6026 (1998).

    [17] [17] C. K. Hitzenberger, E. Gotzinger, M. Sticker, M. Pircher, and A. F. Fercher, Opt. Express 9, 780 (2001).

    [18] [18] M. W. Lindner, P. Andretzky, F. Kiesewetter, and G. Hausler, in Handbook of Optical Coherence Tomography B. E. Bouma and G. J. Tearney, (eds.) (Marcel Dekker, New York, 2002) pp.335-357

    [19] [19] Y. Lu and B. Lü, Matrix Optics (in Chinse) (Dalian University of Technology Press, Dalian, 1989) p.322.

    [20] [20] M. R. Hee, D. Huang, E. A. Swanson, and J. G. Fujimoto, J. Opt. Soc. Am. B 9, 903 (1992).

    CLP Journals

    [1] Hongxia Li, Jiyang Fan, Fufang Su, Fuquan Wu, Shining Zhu2**, "Suppressing the disturbance in the transmission spectrum of Glan-Thompson-type prism polarizers," Chin. Opt. Lett. 8, 428 (2010)

    [2] Minghui Chen, Zhihua Ding, Lei Xu, Tong Wu, Chuan Wang, Guohua Shi, Yudong Zhang, "All-fiber ring-cavity based frequency swept laser source for frequency domain OCT," Chin. Opt. Lett. 8, 202 (2010)

    [3] Wang Yi, Chen Xiaodong, Li Haifeng, Li Qiao, Yu Daoyin. Single-Detector Polarization-Sensitive Optical Coherence Tomography for Biological Tissue Imaging[J]. Chinese Journal of Lasers, 2009, 36(10): 2534

    Tools

    Get Citation

    Copy Citation Text

    Qiang Gong, Chuanmao Fan, Fan Zhang, Jianquan Yao, "In vitro birefringence imaging with spectral domain polarization-sensitive optical coherence tomography," Chin. Opt. Lett. 6, 905 (2008)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jun. 18, 2008

    Accepted: --

    Published Online: Dec. 17, 2008

    The Author Email: Qiang Gong (gongqiang@aoe.ac.cn)

    DOI:10.3788/COL20080612.0905

    Topics