Geometric Correction of Fan-Beam X-Ray Fluorescence CT Based on Local Linear Relationship

Shanghai Jiang1、*, Zhizhen Ma1, Binbin Luo1、**, Mingfu Zhao1, Bin Tang1, Shenghui Shi1, Decao Wu1, Xue Zou1, Zourong Long1, and Mi Zhou2
Author Affiliations
  • 1Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection, Chongqing University of Technology, Chongqing 400054, China
  • 2College of Science, Chongqing University of Technology, Chongqing 400054, China
  • show less
    Figures & Tables(14)
    XFCT system. (a) Parallel hole collimated array detector; (b) pinhole collimated array detector
    Fan beam X-ray XFCT schematic
    Deviation of relative position between phantom and detector
    Geometric parameter correction flow chart
    Simulation model and related parameters. (a) Geant4 simulation model; (b) phantom parameters; (c) geometric offset parameters; (d) array detector parameters
    Incident X-ray energy spectrum energy spectrum collected by the fluorescence detection unit. (a) Incident X-ray energy spectrum; (b) energy spectrum collected by the fluorescence detection unit
    Projected sinogram
    Original reconstructed image
    Reconstruction image after offset correction. (a) Reconstructed image after x-axis offset correction; (b) reconstructed image after y-axis offset correction
    Offset parameter varies with the number of iterations. (a) x-axis offset parameter correction; (b) y-axis offset parameter correction
    • Table 1. SpeckCalc parameters

      View table

      Table 1. SpeckCalc parameters

      ParameterValue
      Anode target materialTungsten
      Tube voltage /kVp70
      Beryllium filter thickness /mm0.8
      Aluminum filter thickness /mm1.0
      Copper filter thickness /mm0.4
      Energy resolution /keV0.1
    • Table 2. Geometric parameter error domain and sampling interval

      View table

      Table 2. Geometric parameter error domain and sampling interval

      Parameterx-axis offset /mmy-axis offset /mm
      Error domain[-10, 10][-10, 10]
      Sampling interval0.50.5
    • Table 3. Preset geometric parameters and corrected geometric parameters

      View table

      Table 3. Preset geometric parameters and corrected geometric parameters

      Parameterx-axis offset /mmy-axis offset /mm
      Preset geometric parameter34
      Corrected geometric parameter2.694.37
    • Table 4. Quantitative comparison between the original image and the corrected image

      View table

      Table 4. Quantitative comparison between the original image and the corrected image

      ParameterOriginal reconstructed imageCorrected imagePercentage of parameter change /%
      Information entropy0.71840.6772-5.7
      Average gradient0.12190.13238.5
      Standard deviation20.105121.08894.9
    Tools

    Get Citation

    Copy Citation Text

    Shanghai Jiang, Zhizhen Ma, Binbin Luo, Mingfu Zhao, Bin Tang, Shenghui Shi, Decao Wu, Xue Zou, Zourong Long, Mi Zhou. Geometric Correction of Fan-Beam X-Ray Fluorescence CT Based on Local Linear Relationship[J]. Acta Optica Sinica, 2021, 41(20): 2011002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Apr. 8, 2021

    Accepted: May. 6, 2021

    Published Online: Sep. 30, 2021

    The Author Email: Jiang Shanghai (jiangshanghai@cqut.edu.cn), Luo Binbin (luobinbin@cqut.edu.cn)

    DOI:10.3788/AOS202141.2011002

    Topics